Related Experiment Video
Updated: May 5, 2026

Introduction of Intracapsular Rotary-cut Procedures IRCP: A Modified Hysteromyomectomy Procedures Facilitating Fertility Preservation
Published on: January 17, 2019
Hysteroscopic Removal of an Intrauterine Contraceptive Device Obstructed by Polyps: A Case Study
Aishwarya Gupta1, Sandhya Pajai1, Lucky Srivani Reddy1
1Department of Obstetrics and Gynaecology, Datta Meghe Institute of Higher Education and Research, Wardha, IND.
Abstract:
In this case report, a patient presented with an intrauterine contraceptive device (IUD) obstruction caused by the presence of an endometrial polyp. Despite IUDs being known for their effectiveness as long-term contraceptives, it is important to note that intrauterine abnormalities can compromise their functionality. The obstruction was successfully diagnosed and treated using hysteroscopy, a minimally invasive procedure that enables direct visualization and removal of the polyp. This case highlights the important role of hysteroscopy in managing the complications associated with intrauterine devices.
More Related Videos
11:29Surgical Techniques to Optimize Ovarian Reserve during Laparoscopic Cystectomy for Ovarian Endometrioma
Published on: January 22, 2022
03:01Author Spotlight: A Reproductive Hysteroscopy Approach for Complete Endometrial Polyp Removal and Enhanced Endometrial Receptivity
Published on: August 2, 2024