Related Experiment Video
Updated: May 25, 2025

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Extracellular Matrix Proteins Improve Risk Prediction in Patients Undergoing Transcatheter Aortic Valve Replacement
Felicitas Boeckling1,2,3, Tina Rasper1, Lukas Zanders1,2,3
1Institute for Cardiovascular Regeneration, Goethe University Frankfurt am Main Germany.
Background:
Cardiac fibrosis is common in patients with severe aortic stenosis and an independent predictor of death. Therefore, we examined the additional value of circulating fibrosis markers as a putative biomarker platform to identify patients with aortic stenosis undergoing transcatheter aortic valve replacement (TAVR) who are at a higher risk of death.
Methods:
In this study, 2-year survival analyses were conducted in 378 consecutive patients undergoing TAVR to evaluate the association between fibrosis marker and risk of adverse long-term outcome. Implementation of fibrosis marker into TAVR risk stratification was tested by a machine-learning algorithm.
Results:
Among 20 circulating fibrosis markers involved in pathological extracellular matrix remodeling, high tissue inhibitor of metalloproteinase-1 (TIMP-1) levels independently predicted risk of death in univariable (hazard ratio, 5.0 [95% CI, 2.6-9.7]; P<0.001) and multivariable (adjusted hazard ratio, 2.2 [95% CI, 1.0-4.7]; P=0.046) Cox regression analyses. Consequently, higher TIMP-1 levels offered a significantly higher overall prediction of reduced survival compared with the conventional Society of Thoracic Surgeons Predicted Risk of Mortality score (area under the curve, 0.753 [95% CI, 0.682-0.824] versus area under the curve, 0.656 [95% CI, 0.578-0.734]; P<0.05). Applying an independent machine-learning algorithm allowed identification of a simple combination of 2 biomarkers (TIMP-1 and high-sensitivity cardiac troponin T) with superior prognostic value compared with Society of Thoracic Surgeons Predicted Risk of Mortality alone (area under the curve, 0.757 [95% CI, 0.686-0.828] versus 0.656 [95% CI, 0.578-0.34]; P<0.05).
Conclusions:
Circulating TIMP-1 is an independent predictor of reduced 2-year overall survival in patients undergoing TAVR. Combined with high-sensitivity cardiac troponin T, circulating TIMP-1 should be incorporated into risk stratification to identify patients undergoing TAVR who are at a higher risk of death.
More Related Videos
Related Concept Videos
Intracellular Signaling Affects Focal Adhesions
Some...
Extracellular Matrix