Detrended fluctuation analysis of day and night breathing parameters from a wearable respiratory holter
Alessandra Angelucci1, Andrea Aliverti1
1Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy.
Background And Objective:
This study focuses on the application of Detrended Fluctuation Analysis (DFA) to understand the variability and correlation properties of respiratory parameters time series obtained by means of a wearable.
Methods:
Data from 18 healthy volunteers collected using the Airgo™ band, which provides signals proportional to thoracic circumference at a sampling frequency of 10 Hz. The primary aim was to provide preliminary normative data for DFA scaling factors.
Results:
DFA was applied to 6-h recordings, revealing significant differences (p < 0.001) in scaling factors (α values) for tidal volume (night: 0.97 [0.09], day: 0.88 [0.04]), minute ventilation (night: 1.02 [0.10], day: 0.91 [0.07), mean inspiratory flow (night: 0.98 [0.06], day: 0.88 [0.06]), mean expiratory flow (night: 0.89 [0.08], day: 0.81 [0.06]), and duty cycle (night: 0.64 [0.04], day: 0.59 [0.03]). Quadratic detrending highlighted additional differences not captured with linear detrending, particularly in inspiratory and expiratory time. These findings suggest distinct regulatory patterns during sleep.
Conclusions:
DFA analysis of respiratory parameters obtained from wearable devices reveals distinct regulatory patterns between day and night conditions, particularly in parameters related to tidal volume and ventilation. These findings demonstrate the potential of DFA to uncover physiological differences in respiratory control mechanisms, especially during sleep, despite technical limitations such as the strong dependency of DFA scaling factors on sampling frequency, duration, and detrending order. Future research should address the limitations of sample size and expand normative datasets to include individuals with respiratory conditions, to translate this methodology into specific clinical applications.
More Related Videos
09:13Method to Obtain Pattern of Breathing in Senescent Mice through Unrestrained Barometric Plethysmography
Published on: April 28, 2020
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory Volumes and Capacities I