Related Experiment Video
Updated: May 10, 2026

Stem Cell Transplantation Strategies for the Restoration of Cognitive Dysfunction Caused by Cranial Radiotherapy
Published on: October 18, 2011
A New Approach to Highly Conformal Hippocampal-sparing Whole-brain Radiotherapy: A Feasibility Study
Christian Ziemann1, Florian Cremers2, Miller MacPherson3
1Department of Radiation Oncology, University of Lübeck, Lübeck, Germany; christian.ziemann@uksh.de.
Background/Aim:
Hippocampal-sparing whole-brain radiotherapy (HS-WBRT) is increasingly used for multiple brain metastases. However, most studies have not reported dose conformity indices (CI). In the only study indicating the CI, conformity was low (CI=0.7). We developed a new technique to achieve a significantly higher CI and better dose coverage.
Patients And Methods:
Ten patients received 30 Gy of HS-WBRT for brain metastases. Three variants of treatment plans (VAR1, VAR2, VAR3) were investigated. Volumetric modulated arc therapy plans with two (2ROT) or three rotations (3ROT) were created for each variant. Plans were compared for compliance with hippocampal sparing criteria, CI (where a higher value indicates better conformity), and homogeneity index (HI, where a lower value indicates better homogeneity).
Results:
Best results (highest CI, lowest HI) were achieved with the VAR3-3ROT technique (a new method), which yielded a CI=0.92-0.95 and a HI=0.05-0.09. VAR3-2ROT led to a CI=0.90-0.95 and a HI=0.06-0.11. With the other techniques, CI and HI ranged between 0.77-0.87 and 0.15-0.32, respectively.
Conclusion:
Our new technique achieved both appropriate hippocampal sparing and very high dose conformity of ≥0.9. Significant underdosage outside the hippocampal-sparing area was avoided.