Related Experiment Video
Updated: May 25, 2025

Atomic Force Microscopy Cantilever-Based Nanoindentation: Mechanical Property Measurements at the Nanoscale in Air and Fluid
Published on: December 2, 2022
Ball Tip Feeler vs. Depth Gauge: Detection of Bony Pedicle Defects Before Pedicle Screw Insertion
Ulf Brunnemer1,2, Sabine Roth1, Christian W Müller1,3
1Department of Trauma Surgery, Hannover Medical School, Hannover, Germany.
Background/Aim:
The objective of this study was to investigate whether the detection rates of pedicle breaches depended on the surgeon's experience level and whether different instruments resulted in varied palpation quality.
Materials And Methods:
Experienced surgeons (ES) (n=8) and inexperienced surgeons (IS) (n=10) were compared. The study was performed using a sawbone model of the spine. Pedicle defects were created at various positions and levels. Participants detected and located the bony defects using a depth gauge and a straight ball tip feeler. After the first measurement, the IS group underwent training focused on identifying bone defects. The experiment was repeated after three weeks under identical conditions.
Results:
A significant difference was found between ES and IS in the time required to palpate pedicles and bony defects using the ball tip feeler during the first measurement (297.2±114.4 s vs. 202.1±77.9 s; p=0.05). However, after training and during the second measurement three weeks later, these differences were no longer observed (223.7±65.1 s vs. 212.2±73.6 s; p=0.73). Notably, no significant differences were found in the accuracy in detecting bony pedicle defects between the two groups, regardless of the device used. Furthermore, no improvement was found in the IS group after training, regardless of the device used.
Conclusion:
ES and IS accurately detected pedicle breaches without significant differences. Training did not affect detection rates between the groups, and the choice of device did not affect the accuracy of pedicle breach detection.
More Related Videos
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessment of the Abdomen III: Palpation
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...