Related Experiment Video
Updated: May 25, 2025

Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
Published on: September 4, 2017
DEXA Result Automation into Radiology Reports: An Implementation Guide for Radiologists, PACS Administrators, and
Nathan A Bumbarger1, Stephanie Y Jo2, Brandon J Cofield3
1Wilford Hall Ambulatory Surgical Center, Lackland Air Force Base, Bexar County, TX, USA. nathan.bumbarger@gmail.com.
None:
Osteoporosis is prevalent among older adults, significantly increasing fracture risk, with hip fractures often leading to reduced survival. Dual-energy X-ray absorptiometry (DEXA) is the gold standard for diagnosing osteoporosis. However, manual transcription of DEXA results into radiology reports is error-prone and time-consuming. This study explores the implementation of a vendor-neutral structured report (SR) system to automate data import from DEXA scans, aiming to improve efficiency and accuracy. The study involved the use of Nuance PowerScribe 360 and Hyland's PACSgear ModLink for automating DEXA data entry into radiology reports. ModLink translates DEXA results into structured data, which is mapped to customized report templates. Radiologists compared the templates with and without the SR data being sent, analyzing time differences between the two templates using pre- and post-implementation measurements. The implementation of the SR system led to a significant reduction in report generation time, with radiologists achieving up to a fivefold decrease in dictation time. The slowest reader saw a 2.5-fold improvement, and the fastest reader showed a fivefold improvement (p < 0.01). No errors in data mapping were observed, indicating reliable integration of the SR system. In light of the current radiologist shortage, the SR system demonstrated notable improvements in workflow efficiency without adding to technologist workload. The time savings and reduced transcription errors offer radiology practices a valuable tool to enhance productivity and patient care. Automating the DEXA data transcription process using a structured report system substantially improves efficiency, minimizes errors, and has minimal implementation burden, representing a promising intervention for radiology practices facing increasing demand.
Related Concept Videos
X-ray Imaging
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Data Reporting and Recording

