DiCARTTM device to measure capillary refill time: a validation study in patients with acute circulatory failure
Alexandre Descamps1,2, Matthias Jacquet-Lagrèze1,2,3, Thomas Aussal1
1Service d'anesthésie-réanimation, Hôpital cardiologique Louis Pradel, Hospices Civils de Lyon, Bron, France.
None:
Capillary Refill Time (CRT) is a valuable metric to assess cutaneous perfusion. Its prognostic value in patients with acute circulatory failure has been reported as improved when the measurement is standardized. The DiCART™ device is a fully automated CRT measurement tool requiring validation. We conducted a comparative interventional single-center study including 25 patients with acute circulatory failure, to evaluate the agreement between CRT measured by an automated measurement device (CRTDiCART) and CRT measured clinically (CRTCLIN). CRT was measured on the fingertip, chest, and knee. Three measurements were performed at each location to obtain an average for each site. The measurements were conducted both clinically and using the DiCART™ device by two different operators, each blinded to the results. Agreement was determined using intraclass correlation coefficient (ICC) and Bland and Altman analysis. The ICC between CRTCLIN and CRTDiCART was 0.46 (95% Confidence Interval (CI) 0.32, 0.59) across all measurement sites; the mean bias was 0.23s (95% CI -0.17, 0.64), with upper Limit of Agreement (LoA) 2.77s (95% CI 2.44, 3.20) and lower LoA - 2.30s (-2.73, -1.97). Intra observer ICC was 0.85 (95% CI 0.74, 0.91) for CRTCLIN and 0.43 (95% CI 0.15, 0.64) for CRTDICART. Inter observer ICC was 0.86 (95% CI 0.76, 0.92) for CRTCLIN and was 0.41 (95% CI 0.14, 0,63) for CRTDICART. The DiCART™ device showed poor agreement with clinical CRT in patients with acute circulatory failure, which does not support its use in routine practice.
More Related Videos
07:37Performing an In Vitro Genome-Wide CRISPR Knockout Screen in Chimeric Antigen Receptor T Cells
Published on: January 31, 2025
06:08Assessment of Chimeric Antigen Receptor T Cell-Associated Toxicities Using an Acute Lymphoblastic Leukemia Patient-Derived Xenograft Mouse Model
Published on: February 10, 2023
Related Concept Videos
Cartesian Vector Notation
Cartesian Form for Vector Formulation
Vector Components in the Cartesian Coordinate System
Methods of Documentation IV: Focus Charting
It typically involves three columns for recording information:
Pie Chart
In a pie chart, the central angle, the arc length of each slice, and the area are directly proportional to the quantity or percentage it represents. Some real-world examples that can be depicted using pie charts include marks obtained by students...
Guidelines and Strategies for Safe Computer Charting
Maintain Confidentiality and Security: