Related Experiment Video
Updated: May 25, 2025

Stereolithographic 3D Printing with Renewable Acrylates
Published on: September 12, 2018
Effects of post-curing conditions on degree of conversion, microhardness, and stainability of 3D printed permanent
Sultan Aktug Karademir1, Samet Atasoy2, Serdar Akarsu2
1Department of Restorative Dentistry, Faculty of Dentistry, Ordu University, Ordu, 52200, Ordu, Turkey. Sultan_721@hotmail.com.
Background:
The aim of this in-vitro study is to investigate the effect of post-curing time and units on the degree of conversion (DC), microhardness (VHN) and staining susceptibility (∆E00) of two 3D printed permanent resins (Crowntec (SCT), Varseosmile CrownPlus (VSP)).
Methods:
A total of 180 disc-shaped samples (10*10*2 mm), 60 for each experiment, from the tested materials (30 SCT, 30 VSP) were printed on 3D printer. Half of the samples were post-cured in LC-3DPrint Box and the other half in Phrozen Cure V2 and were divided into 3 subgroups according to post-curing time of 5, 10 and 30 min (n = 5). The DC of the samples was determined using a Fourier transform infrared spectrometer. The VHN values were measured with a Vickers hardness tester. The color of the samples was initially measured using a spectrophotometer and then again after one month of staining in coffee. The ∆E00 was calculated with the CIEDE2000 formula. Data obtained from each parameter examined were analyzed by SPSS software using One-Way ANOVA, post-hoc Tukey, post-hoc Tamhane's T2, Independent-samples T test and Pearson's correlation test (α = 0.05).
Results:
While DC and VHN of the tested materials increased in parallel with the post-curing time, ∆E00 decreased. The highest DC (74.6 ± 3.8) and VHN (29.1 ± 0.8) and the lowest ∆E00 (1.9 ± 0.1) were obtained in LC-3DPrint Box-30 min post-curing group of VSP. The effect of the type of post-curing units on the DC and ∆E00 of the materials was statistically significant (p < 0.05) except for the SCT-5 min and SCT-30 min groups. The VHN was statistically significantly higher in LC-3DPrint Box at all post-curing times of the tested materials (p < 0.05). A significant positive correlation was found between DC and VHN (r = 0.796, p < 0.001), while a significant negative correlation was observed between DC and ∆E00 (r=-0.763, p < 0.001).
Conclusion:
The study demonstrated that extending the post-curing time led to improvements in the degree of conversion and microhardness, while simultaneously reducing the stainability of the materials tested. Additionally, the type of post-curing unit used had a significant impact on these results, further highlighting the importance of both curing time and equipment in optimizing material properties.
More Related Videos
03:37Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
07:283D Printing and In Situ Surface Modification via Type I Photoinitiated Reversible Addition-Fragmentation Chain Transfer Polymerization
Published on: February 18, 2022
Related Concept Videos
Curing Methods
Curing of Concrete
Accelerated Curing of Concrete
Drying Shrinkage
A portion of this drying shrinkage can be reversed; if the concrete is...