Nasopharyngeal Airspace Temperature During Rhinothermy
Grace Bird1, Sophie Sharpe2, Irene Braithwaite1
1Drs. Bird and Braithwaite are affiliated with Medical Research Institute of New Zealand, Wellington, New Zealand.
None:
Background: Respiratory viruses such as influenza and human rhinoviruses are temperature sensitive. Rhinothermy delivers heated, humidified air to the upper airways via the nares, and by possibly inhibiting viral replication, it is proposed as a potential therapy to attenuate the severity and duration of common cold or influenza symptoms. The effect of rhinothermy on nasopharyngeal air space temperature is uncertain. The objective of this study was to investigate the effect of rhinothermy delivering 100% humidified air at 41°C on nasopharyngeal air space temperature. The hypothesis was that the mean nasopharyngeal air space temperature while nose breathing would be within 1.5°C of the device's set dew point temperature of 41°C. Methods: In this single-center nonblind nonrandomized parallel arm interventional study, nasopharyngeal air space temperature was continuously measured during delivery of 100% humidified air via a nasal high-flow device at 41°C and 30-35 L/min (rhinothermy [rNHF]) (n = 6), and at 31°C and 10 L/min ('sham' rhinothermy) (n = 6). The primary outcome measure was mean nasopharyngeal air space temperature during delivery of rNHF while nose breathing. Change in nasopharyngeal air space temperature during nose breathing and mouth breathing was compared for both interventions. Results: Twelve participants age 18-75 years were recruited. The mean (SD) nasopharyngeal air space temperature during rNHF at 41°C while nose breathing was 37.9°C (1.22) and with sham rhinothermy at 31°C was 36.8°C (0.18). There was no significant difference in nasopharyngeal air space temperature between nose and mouth breathing for both interventions combined (difference [95% CI] -0.1°C [-0.59 to 0.36], P = .60). Conclusions: The mean nasopharyngeal air space temperature during rNHF while nose breathing was not within 1.5°C of the device's set dew point temperature of 41°C. rNHF temperatures may need to be set considerably higher than the target nasopharyngeal air space temperature when investigating the effect of rhinothermy on symptom severity or duration of respiratory infections caused by viruses with temperature-dependent replication.
Related Concept Videos
Suctioning the Nasopharyngeal Airway
Equipment Required
Epistaxis
Etiology
Possible causes of this condition include high blood pressure, trauma, low humidity, upper respiratory tract infections, allergies, foreign bodies, nasal inhalation of corticosteroids or illicit drugs, excessive use of decongestant nasal sprays, facial or nasal surgery, anatomic malformation, tumors, or systemic...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Anatomy of Respiratory System I: Upper Respiratory Tract
Nose and nasal cavity
The nose and nasal cavity represent the main external openings of the respiratory tract....
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...