Bed sensor ballistocardiogram for non-invasive detection of atrial fibrillation: a comprehensive clinical study
Jonas Sandelin1, O Lahdenoja1, I Elnaggar1
1Department of Computing, Digital Health Technology Group, University of Turku, Vesilinnantie 3, 20500 Turku, Finland.
Abstract:
Objective.Atrial fibrillation (AFib) is a common cardiac arrhythmia associated with high morbidity and mortality, making early detection and continuous monitoring essential to prevent complications like stroke. This study explores the potential of using a ballistocardiogram (BCG) based bed sensor for the detection of AFib.Approach.We conducted a comprehensive clinical study with night hospital recordings from 116 patients, divided into 72 training and 44 test subjects. The study employs established methods such as autocorrelation to identify AFib from BCG signals. Spot and continuous Holter ECG were used as reference methods for AFib detection against which BCG rhythm classifications were compared.Results.Our findings demonstrate the potential of BCG-based AFib detection, achieving 94% accuracy on the training set using a rule-based method. Furthermore, the machine learning model trained with the training set achieved an AUROC score of 97% on the test set.Significance.This innovative approach shows promise for accurate, non-invasive, and continuous monitoring of AFib, contributing to improved patient care and outcomes, particularly in the context of home-based or hospital settings.
More Related Videos
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
05:03Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...