High-resolution and high-fidelity diffusion tensor imaging of cervical spinal cord using 3D reduced-FOV multiplexed
Chenglang Yuan1, Shihui Chen1,2, Liyuan Liang1,2
1Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong, China.
Purpose:
To develop a 3D isotropic high-resolution and high-fidelity cervical spinal cord DTI technique for addressing the current challenges existing in 2D cervical spinal cord DTI.
Methods:
A 3D multi-shot DWI acquisition and reconstruction technique was developed by combining 3D multiplexed sensitivity encoding (3D-MUSE) with two reduced FOV techniques, termed 3D-rFOV-MUSE, to acquire 3D cervical spinal cord DTI data using a sagittal thin slab. A self-referenced 2D ghost correction method and a 2D navigator-based inter-shot phase correction were integrated into the reconstruction framework to simultaneously eliminate Nyquist ghost and aliasing artifacts. Cardiac triggering was used during data acquisition to minimize the influence of cerebrospinal fluid pulsation. In vivo experiments were conducted on five healthy subjects at a 1.5 T MRI scanner for evaluating the feasibility of 3D cervical spinal cord DTI using 3D-rFOV-MUSE in terms of geometric fidelity, reconstruction performance, and SNR efficiency.
Results:
A 3D-rFOV-MUSE can achieve high-resolution cervical spinal cord DTI at 1.0 mm isotropic resolution. The integration of reduced FOV and multi-shot acquisitions can improve the geometric fidelity of 3D cervical spinal cord DTI. Compared with routine 2D single-shot diffusion-weighed EPI (2D-ss-EPI), the proposed technique can mitigate through-plane partial volume effect and enable multi-planar data reformation for cervical spinal cord DTI, with effective reductions of distortions and improved signal-to-noise ratio.
Conclusion:
We demonstrated the feasibility of high-resolution and high-fidelity 3D cervical spinal cord DTI at 1.0 mm isotropic resolution using 3D-rFOV-MUSE technique, which may potentially improve the quantitative assessment of cervical spinal cord DTI biomarkers.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Magnetic Resonance Imaging
Spinal Cord: Cross-sectional Anatomy
Gray Matter and its Components
Central to the gray matter is...
Imaging Studies IV: Magnetic Resonance Imaging