Related Experiment Video
Updated: Jul 29, 2026

Novel Diagnostics in Revision Arthroplasty: Implant Sonication and Multiplex Polymerase Chain Reaction
Published on: December 3, 2017
Management of an infected metacarpophalangeal joint replacement with a temporary articulated cement spacer
Michael M Kamiza1, Timothy J Halsey1
1Department of Trauma and Orthopaedics, The Rotherham NHS Foundation Trust, Rotherham, UK.
Abstract:
We present a case of a 63-year-old woman with an infected metacarpophalangeal arthroplasty, treated with an articulating cement spacer over a K-wire framework. This technique maintained joint movement during the management of the infection, leading to a positive functional outcome.Level of evidence: V.
Related Concept Videos
Hand hygiene
Hand washing...
Handwashing II: Pre-procedure and Initial Procedure Steps
The hand washing procedure itself includes the following steps. First, cover cuts, if any, on hands with a waterproof dressing. Cuts and abrasions can become contaminated with bacteria hindering the ability to clean the area thoroughly. In addition, repeated hand washing can worsen an injury. The nails must be short and clean, without nail paint...