Room Temperature and Humidity Resistant NH3 Detection Based on a Composite of Hydrophobic CNTs with Sulfur Nanosheets
Xiaoni Cui1,2, Huaipeng Wang3, Xinglei Wang1
1College of Chemistry and Chemical Engineering, Key Laboratory of Pollutant Chemistry and Environmental Treatment, Yili Normal University, Yining 835000, China.
Abstract:
A composite of sulfur nanosheets (S-NSs) with hydrophobic carbon nanotubes (H-CNTs) was designed, and a chemiresistive gas sensor based on this composite material was constructed for breath analysis of NH3 detection at room temperature. Taking advantage of the capillary condensation of CNTs, the hydrophobic effect of hexadecyltrimethoxysilane (HDTMS), and the high sensitivity of S-NSs to NH3 detection, the constructed sensor showed an improved humidity-resistant capacity and is capable of detecting breath-relevant NH3 concentrations down to ppb level under high humidity. The fabricated gas sensor exhibited fast response/recovery (18/26 s) and good stability. Online monitoring for exhaled breath analysis shows good recovery with a stable baseline, providing a potential practical application. The research also facilitates the development of commercial low-cost breath analysis sensors.
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Factors Affecting Body Temperature
Factors may include:
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Requirements for Human Life
Oxygen
Atmospheric air is only about 20 percent oxygen, but that oxygen is a key component of the chemical reactions that keep the body alive, including the reactions that produce ATP. Brain cells are susceptible to a lack of oxygen because they require a...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...


