Differences in Direct Fick and Thermodilution Measurements of Cardiac Output: Impact on Pulmonary Hypertension
Garry W Hamilton1,2, Luke R Fletcher3,4,5, William Harley1
1Department of Cardiology Austin Health Heidelberg Australia.
Abstract:
Direct Fick (DF) and bolus thermodilution (TD) are endorsed by pulmonary hypertension (PH) guidelines to measure cardiac output. In contemporary practice, agreement between methods is unknown, as are the diagnostic consequences of disagreement. We sought to evaluate the frequency and degree of disagreements between cardiac output measurement techniques and assess their impact on the hemodynamic assessment of PH. This was a single-center study that included 182 patients who had cardiac output concurrently measured by DF and TD. Oxygen consumption was measured by indirect calorimetry. Agreement between DF and bolus TD cardiac output was assessed using Bland-Altman analysis. The median DF and TD cardiac outputs were 5.42 L/min (interquartile range [IQR] 3.90-7.41) and 4.10 L/min (IQR 3.47-5.10), respectively. Significant disagreement was observed with DF yielding higher cardiac output results than TD. Mean error was proportional to cardiac output (-3.75% at 3 L/min to +44.5% at 7 L/min), and limits of agreement were wide. Disagreement was increased by 19.2% in the presence of least moderate tricuspid regurgitation and by 16.0% in patients with atrial fibrillation. Among 152 patients with PH, hemodynamic classification discordance occurred in 18 (11.8%) patients. Disagreement between DF and TD was observed, which resulted in a discrepant hemodynamic classification in approximately 12% of patients. These techniques should, therefore, not be used interchangeably for serial surveillance, and without a clinical gold standard, a rationale exists for utilizing both methods concurrently in certain clinical situations.
Related Concept Videos
Pulmonary Hypertension: Classification and Pathogenesis
There are various classifications for PH, each relating to different underlying causes and also...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...