Related Experiment Video
Updated: May 24, 2025

Cell-free Biochemical Fluorometric Enzymatic Assay for High-throughput Measurement of Lipid Peroxidation in High Density Lipoprotein
Published on: October 12, 2017
Cardiovascular disease lipids and lipoproteins biomarker standardization
Alicia N Lyle1, Uliana Danilenko1, Otoe Sugahara1
1Division of Laboratory Sciences, Centers for Disease Control and Prevention (CDC), Atlanta, GA, USA.
Insights
Standardizing cardiovascular disease (CVD) biomarkers ensures accurate risk assessment. New apolipoprotein measurements offer improved CVD risk detection, highlighting the need for ongoing standardization efforts for better patient care.
Area of Science:
- Clinical Chemistry
- Biomarker Standardization
- Cardiovascular Disease Risk Assessment
Background:
- Cardiovascular disease (CVD) remains a leading global cause of mortality.
- Clinical practice guidelines for CVD risk assessment and treatment have evolved.
- Accurate measurement of lipid and lipoprotein biomarkers is crucial for effective CVD management.
Purpose of the Study:
- To review changes in CVD biomarker measurements aligned with evolving clinical guidelines.
- To discuss the comparability and standardization status of traditional and newer CVD biomarkers.
- To highlight the importance of assay standardization for reliable CVD risk assessment.
Main Methods:
- Review of changes in CVD lipid and lipoprotein biomarker measurements.
- Discussion of assay standardization factors: calibration, analytical sensitivity, selectivity, and stability.
- Analysis of the current standardization status for key biomarkers including LDL-C, HDL-C, Lp(a), and apolipoproteins (apo) A-I and B.
Main Results:
- Standardization ensures comparable and reliable biomarker measurements, essential for clinical practice.
- Apolipoproteins (apoB and Lp(a)) may offer more accurate CVD risk assessment than traditional lipids.
- The Centers for Disease Control and Prevention (CDC) CVD Biomarkers Standardization Program (BSP) maintains standardization for blood lipids.
Conclusions:
- Ensuring comparability and reliability of CVD biomarker measurements through standardization is critical for guideline implementation and patient care.
- New reference systems for apoA-I and B are needed, emphasizing the importance of collaborative networks for standardization sustainability.
- The CDC CVD BSP will continue to enhance the standardization of traditional and emerging CVD biomarkers.
Abstract:
Cardiovascular disease (CVD) is the leading cause of mortality in the United States and globally. This review describes changes in CVD lipid and lipoprotein biomarker measurements that occurred in line with the evolution of clinical practice guidelines for CVD risk assessment and treatment. It also discusses the level of comparability of these biomarker measurements in clinical practice. Comparable and reliable measurements are achieved through assay standardization, which not only depends on correct test calibration but also on factors such as analytical sensitivity, selectivity, susceptibility to factors that can affect the analytical measurement process, and the stability of the test system over time. The current status of standardization for traditional and newer CVD biomarkers is discussed, as are approaches to setting and achieving standardization goals for low-density lipoprotein cholesterol (LDL-C), high-density lipoprotein cholesterol (HDL-C), total cholesterol (TC), triglycerides (TG), lipoprotein(a) (Lp(a)), apolipoproteins (apo) A-I and B, and non-HDL-C. Appropriate levels of standardization for blood lipids are maintained by the Centers for Disease Control and Prevention's (CDC) CVD Biomarkers Standardization Program (CDC CVD BSP) using the analytical performance goals recommended by the National Cholesterol Education Program. The level of measurement agreement that can be achieved is dependent on the characteristics of the analytes and differences in measurement principles between reference measurement procedures and clinical assays. The technical and analytical limitations observed with traditional blood lipids are not observed with apolipoproteins. Additionally, apoB and Lp(a) may more accurately capture CVD risk and residual CVD risk, respectively, than traditional lipids, thus prompting current guidelines to recommend apolipoprotein measurements. This review further discusses CDC's approach to standardization and describes the analytical performance of traditional blood lipids and apoA-I and B observed over the past 11 years. The reference systems for apoA-I and B, previously maintained by a single laboratory, no longer exist, thus requiring the creation of new systems, which is currently underway. This situation emphasizes the importance of a collaborative network of laboratories, such as CDC's Cholesterol Reference Methods Laboratory Network (CRMLN), to ensure standardization sustainability. CDC is supporting the International Federation of Clinical Chemistry and Laboratory Medicine's (IFCC) work to establish such a network for lipoproteins. Ensuring comparability and reliability of CVD biomarker measurements through standardization remains critical for the effective implementation of clinical practice guidelines and for improving patient care. Utilizing experience gained over three decades, CDC CVD BSP will continue to improve the standardization of traditional and emerging CVD biomarkers together with stakeholders.
Related Concept Videos
Blood Studies for Cardiovascular System II: CRP, Hcy, and Cardiac Natriuretic Peptide Markers
These markers indicate stress or strain on the heart muscle:
Natriuretic Peptides (BNP)
Cardiac myocytes produce these hormones in response to ventricular stretching...
Blood Studies for Cardiovascular System III: Serum Lipid Profile
Serum lipids are fats and fatty substances in the blood and are crucial for various bodily functions, including energy storage, cellular structure, and hormone production. Serum lipids consist of cholesterol, triglycerides, and phospholipids.
Cholesterol is a soft, fat-like substance found in all body cells. It is crucial for producing hormones, vitamin D, and substances that aid...
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Lipid-derived Compounds in the Human Body
Fat-soluble Vitamins
Fat-soluble vitamins, including vitamins A, D, E, and K, are required in minimal quantities, but their deficiencies can lead to severely abnormal physiological conditions. For example, vitamin A deficiency can cause night blindness, dry skin,...
Cholesterol: Significance and Regulation
Considering cholesterol and...
Lipid-Lowering Drugs: Statins and Miscellaneous Agents