A low-profile all-suture anchor construct provides comparable fixation to both spiked washer and bone staple for
Felipe Moreira Borim1, Lachlan Batty2, Cindy Zeng3
1Melbourne Orthopaedic Group, Melbourne, Australia; Biomedical Engineering - The University of Melbourne, Melbourne, Australia; Teknon Medical Center, Barcelona, Spain; Surgery and Morphological Sciences - Universitat Autónoma de Barcelona, Barcelona, Spain. Electronic address: https://in.linkedin.com/felipemborim.
Objectives:
To compare the biomechanical performance of an all-suture anchor construct to that of both a spiked washer and cancellous screw, and a bone staple in tibial-sided superficial medial collateral ligament (sMCL) reconstruction.
Methods:
A time-zero cadaveric biomechanical study was conducted using 24 human cadaveric tibia, with fresh-frozen peroneus longus allografts used for an sMCL reconstruction. Specimens were randomized to one of three treatment groups for tibial fixation being an all-suture anchor construct, spiked washer, or bone staple. A servohydraulic uniaxial testing machine was used to assess elongation after 1000 cycles at 20-50N, maximum load-to-failure (LTF), elongation at maximum LT, and modes of failure. Differences between groups were analyzed using one-way analysis of variance (ANOVA).
Results:
No statistically significant differences were observed across the groups. Mean elongation after cyclic loading was 1.1 ± 0.7 mm in the all-suture anchor group, 0.6 ± 1.2 mm in the spiked washer group, and 1.1 ± 0.6 mm in the staple group (p = 0.732). Mean maximum LTF was 132.1 ± 40.2N for the all-suture anchor group, 120.8 ± 54.9N for the spiked washer group, and 123.9 ± 64.1N for the staple group (p = 0.605). Mean elongation at maximum LTF was 8.6 ± 4.1 mm for the all-suture anchor group, 8.7 ± 5.4 mm for the spiked washer group, and 10.8 ± 6.3 mm for the staple group (p = 0.605). The mode of failure for all specimens was tendon pullout.
Conclusion:
The all-suture anchor construct demonstrated comparable performance to both the spiked washer and bone staple for tibial-sided sMCL reconstruction in this time-zero cadaveric biomechanical assessment.
Level Of Evidence:
Level III.
More Related Videos
Related Concept Videos
Bone Structure
Static Equilibrium - II
Anchoring Junctions
Bone as Supporting Connective Tissue
Bone Matrix
Bone, or osseous tissue, is a connective tissue that has a large amount of two different types of matrix material. The organic matrix is similar to the matrix material found in other connective tissues, including some amount of collagen and elastic fibers. This gives strength and flexibility to the tissue. The inorganic matrix consists of mineral salts— mostly calcium salts— that give the...
The Bone Matrix
Spongy Bone
Spongy bone is more porous, and less dense compared to compact bone. It is composed of concentric lamellae that are arranged irregularly to form the trabecular network. In some bones, the spaces between trabeculae contain red marrow, where...