Related Experiment Video
Updated: May 24, 2025

A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Low compression smart clothing for respiratory rate monitoring using a bending angle sensor based on double-layer
Tatsuya Kobayashi1, Daisuke Goto1, Yusuke Sakaue2
1Graduate School of Sport and Health Science, Ritsumeikan University, Shiga, 525-8577 Japan.
Abstract:
In chronic respiratory diseases, continuous self-monitoring of vital signs such as respiratory rate aids in the early detection of exacerbations. In recent years, the development of smart clothing, such as garments equipped with sensors to measure respiratory rate, has been a focus of research. However, the usability and adoption of smart clothing are often compromised owing to the discomfort caused by compression pressure during wear. This study developed smart clothing designed to measure respiratory rate using a low compression pressure. This was achieved by integrating a bending angle sensor, based on double-layer capacitance, into the rib cage and abdomen areas. The accuracy of the respiratory rate measurement was evaluated in 20 healthy male subjects without respiratory diseases. Breathing was measured while the subjects wore the smart clothing and performed breathing exercises in sitting, supine, and lateral postures, following a metronome set between 12 and 30 bpm. To assess accuracy, the respiratory rate measured by the smart clothing was compared with that measured by a spirometer. The recorded compression pressure was 0.77 ± 0.21 kPa, with no subjects reporting discomfort. Correlation coefficients for respiratory rate in the different postures ranged within 0.97-0.99. The mean difference between the smart clothing and spirometer measurements was less than 0.1 bpm. The low mean difference indicated that the proposed low compression pressure wearable respiration sensor, employing a bending angle sensor based on double-layer capacitance, could measure respiratory rate accurately without causing discomfort and within an acceptable error range.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
10:03Conformable Wearable Electrodes: From Fabrication to Electrophysiological Assessment
Published on: July 22, 2022
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...