Misidentification of Medical Devices With Radiographic Contrast Functions As Retained Foreign Bodies on Postoperative
Shuji Uchimura1,2, Toyoaki Maruta1, Rintarou Kamada3
1Anesthesiology, University of Miyazaki Hospital, Miyazaki, JPN.
Abstract:
Retained foreign bodies (RFBs) during surgery are events that should be completely avoided. Herein, we report two cases where a medical device with a radiographic contrast function was mistakenly identified as RFB due to human error. Radiographs were taken for confirmation to prevent foreign body retention after surgery. Case 1 involved a 71-year-old woman who underwent a laparoscopic bilateral adnexectomy for a right ovarian tumor. Postoperative abdominal radiography revealed a 5-mm spindle-shaped shadow in the pelvic cavity. Retention of a surgical instrument was suspected; however, no abnormalities were detected in the instruments used during surgery. Based on the foreign body's location, the shadow was assumed to be a bladder catheter. After removing the catheter, a repeat radiograph was performed, and the shadow disappeared. This bladder catheter had an X-ray contrast function and was misidentified as RFB. Case 2 involved a 38-year-old woman who underwent laparoscopic resection for pedicle torsion of a right ovarian tumor. Postoperative abdominal radiography revealed a contrast thread in the abdomen. A retained surgical gauze sponge was suspected; however, the instrument count was correct. The position of the gauze sponge was checked using mobile digital radiography equipment, and the object was identified as a cotton ball with an X-ray contrast thread placed in the umbilical wound. Additionally, the appearance of the cotton ball on the radiograph was unknown, which contributed to its misidentification as RFB. Eliminating human errors, including lack of communication and unfamiliarity with medical devices, is essential to prevent the misidentification of RFBs on postoperative radiographs.
More Related Videos
07:48High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue
Published on: September 30, 2022
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation I: X-ray and CT
Magnetic Resonance Imaging
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...