Related Experiment Video
Updated: Jul 30, 2026

Performing Behavioral Tasks in Subjects with Intracranial Electrodes
Published on: October 2, 2014
Influences of electrode density on intracranial seizure localisation: a single-blinded randomised crossover study
Ebenezer O Chinedu-Eneh1, Sharon Chiang1, John P Andrews2
1Department of Neurology, University of California San Francisco, San Francisco, CA, USA; Weill Institute for Neurosciences, University of California San Francisco, San Francisco, CA, USA.
Background:
Successful seizure onset zone (SOZ) localisation for epilepsy surgery often relies upon intracranial recordings. Accurate delineation requires anatomical detail yet influences of intracranial electrode density on clinical variables have not been systematically studied.
Methods:
In this experimental study we compared SOZ localisation between spontaneously captured seizures on higher-density depth and grid electrode arrays (4-5 mm inter-electrode spacing) vs. lower-density resampled versions of those same seizures (8-10 mm spacing). Since traditional review of channel traces would reveal density conditions, we instead projected seizure activity data as heatmaps on patient brain reconstructions and hid electrode locations. Using a single-blinded randomised crossover design, six attending-level epileptologists viewed these visualisations from ten patients under both higher-density and lower-density conditions (n = 120 observations) and digitally annotated SOZs.
Findings:
Inter-rater agreement between epileptologists on annotated margins was moderate (average Cohen's kappa: 0.47) and lower for the lower-density condition (p = 0.021, mixed effects model). Scorer confidence ratings did not differ between higher- and lower-density conditions (p = 0.410). The spatial extents of annotated SOZs for higher-density recordings were 25.4% larger on average (p = 0.011) and always closer to true SOZ extents in computer simulations, relative to lower-density.
Interpretation:
Epileptologists using higher-density depth and subdural intracranial EEG recordings had higher inter-rater agreement and identified larger extents of SOZs compared to lower-density recordings. While further studies assessing surgical outcomes in more patients are needed, these results suggest higher densities of electrodes on already-implanted hardware may reveal sub-centimetre extensions and clearer functional contiguity of the SOZ(s) for better appraisals of pathophysiological margins in epilepsy surgery.
Funding:
This work was supported by the National Institutes of Health through NINDS grant K23NS110920 and through a UCSF Weill Institute for Neurosciences Pilot Award.
More Related Videos
09:00Investigating the Function of Deep Cortical and Subcortical Structures Using Stereotactic Electroencephalography: Lessons from the Anterior Cingulate Cortex
Published on: April 15, 2015
06:58Non-restraining EEG Radiotelemetry: Epidural and Deep Intracerebral Stereotaxic EEG Electrode Placement
Published on: June 25, 2016
Related Concept Videos
Electric Field of a Continuous Line Charge
In calculations of electric fields, symmetry is of great use. For example, while calculating electric fields of continuous charge distributions.
Consider a line element with a...
The Hall Effect