Intelligent fault diagnosis and operation condition monitoring of transformer based on multi-source data fusion and
Jingping Cui1, Wei Kuang2, Kai Geng3
1Ural International Institute of Rail Transit, Shandong Polytechnic, Jinan, 250104, China. cjp_sdp_edu@163.com.
Abstract:
Transformers are important equipment in the power system and their reliable and safe operation is an important guarantee for the high-efficiency operation of the power system. In order to achieve the prognostics and health management of the transformer, a novel intelligent fault diagnosis of the transformer based on multi-source data fusion and correlation analysis is proposed. Firstly, data fusion for multiple components of transformer dissolved gases is performed by an improved entropy weighting method. Then, the combination of bidirectional long short-term memory network, attention mechanism, and convolution neural network is employed to predict the load rate, upper oil temperature, winding temperature data, and the fusion indices of dissolved gas components in the transformer. Furthermore, Apriori correlation analysis is performed on the transformer load rate and upper oil layer, winding temperature, and fusion indices of gas components by support and confidence levels to achieve a predictive assessment of the transformer state. Finally, the validity of the algorithm is verified by applying actual data from a power system monitoring platform. The results show that in the vicinity of sample point 88, the dissolved gas, upper oil temperature, and winding temperature data are not within the normal range of intervals, and it is presumed that the arc discharge phenomenon. Furthermore, the average correct fault diagnosis rate of 100 diagnoses of the transformer fault diagnosis model proposed in this paper is 0.917, and the mean square error of the correct rate is 0.018. The proposed model can achieve the prediction of the accident early warning, to prevent further expansion of the accident.
More Related Videos
10:52Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
06:08A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound
Published on: March 21, 2025
Related Concept Videos
Power System Three-Phase Short Circuits
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Differential Relays
Instrument Transformers
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...