Related Experiment Video
Updated: May 24, 2025

Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
Uncertainty Quantification of Cuffless Blood Pressure with Deep Evidential Regression Model
Abstract:
Cuffless blood pressure (BP) estimation models have been extensively studied in recent years. However, due to aleatoric and epistemic uncertainty, these methods make it difficult to provide reliable and accurate BP estimations meeting the clinical requirement. In this study, we propose a novel method to quantify the uncertainty of the cuffless BP estimation model and combine epistemic uncertainty with conformal prediction to generate a statistically rigorous uncertainty interval (UI). First, we develop a deep evidential regression (DER) model to estimate BP with five features extracted from a noninvasive photoplethysmogram (PPG) signal. The DER model predicts a distribution of the target BP instead of a point estimation, so it can offer an analytical solution for the estimation uncertainty. We then utilize conformal prediction to generate a UI that covers the reference BP with a defined probability. We validate the proposed method on 37 subjects with continuous Finpres BP as a reference. The results show that the mean absolute difference (MAD) of systolic BP (SBP) and diastolic BP (DBP) estimations with the proposed method are 5.56 and 3.18 mmHg, respectively. The estimated UI can capture the reference SBP and DBP with a coverage rate of 94.8% and 95.9%, respectively. The findings indicate that the proposed method has the potential to empower more reliable and accurate cuffless BP measurement.
More Related Videos
08:54Measuring Blood Pressure in Mice using Volume Pressure Recording, a Tail-cuff Method
Published on: May 15, 2009
11:04Quantification of Global Diastolic Function by Kinematic Modeling-based Analysis of Transmitral Flow via the Parametrized Diastolic Filling Formalism
Published on: September 1, 2014
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Errors occurring during blood pressure monitoring
Several factors...
Measurement of Blood Pressure
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.