Abstract:
Accurate sleep assessment is critical to the practice of sleep medicine and sleep research. The recent availability of large quantities of publicly available sleep data, alongside recent breakthroughs in AI like transformer architectures, present novel opportunities for data-driven discovery efforts. Transformers are flexible neural networks that not only excel at classification tasks, but also can enable data-driven discovery through un- or self-supervised learning, which requires no human annotations to the input data. While transformers have been extensively used in supervised learning scenarios for sleep stage classification, they have not been fully explored or optimized in forms designed from the ground up for use in un- or self-supervised learning tasks in sleep. A necessary first step will be to study these models on a canonical benchmark supervised learning task (5-class sleep stage classification). Hence, to lay the groundwork for future data-driven discovery efforts, we evaluated optimizations of a transformer-based architecture that has already demonstrated substantial success in self-supervised learning in another domain (audio speech recognition), and trained it to perform the canonical 5-class sleep stage classification task, to establish foundational baselines in the sleep domain. We found that small transformer models designed from the start for (later) self-supervised learning can match other state-of-the-art automated sleep scoring techniques, while also providing the basis for future data-driven discovery efforts using large sleep data sets.
More Related Videos
Related Concept Videos
Transformers with Off-Nominal Turns Ratios
Types Of Transformers
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Three-Winding Transformers
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
Transformers
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...