Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
Mean Perfusion Pressure Estimation Using Hemodynamics Ohm's Law Towards Unobtrusive Mean Arterial Pressure Estimation
Abstract:
This work proposes a novel approach to estimating mean perfusion pressure, a difference between mean arterial and central venous pressure, using a pulsatile arterial blood pressure and a flow waveform. Using these waveforms, which can be measured, for example, using ultrasound, a vascular resistance downstream at the branch of an arterial tree is estimated. This estimation exploits Ohm's law in hemodynamics during multiple steady states when beat-to-beat variations in arterial pressure occur physiologically. Then, the mean perfusion pressure is estimated by multiplying the vascular resistance with time-averaged flow. A numerical simulation of hemodynamics in a human arterial tree demonstrates the approach. MGHDB records in PhysioNet were used to emulate natural variations of the arterial pressure. The mean and standard deviation of errors in validation are -0.1 and 0.3 mmHg, respectively. This work establishes a theoretical background towards mean arterial pressure estimation and supplements prior works to produce an absolute arterial blood pressure waveform unobtrusively and without calibration.
More Related Videos
12:29Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
Published on: May 30, 2011
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.