Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Ligand-Gated Ion Channel Receptor: Gating Mechanism01:30

Ligand-Gated Ion Channel Receptor: Gating Mechanism

Ligand-gated ion channels are transmembrane proteins that play a vital role in intercellular communication and functions of the nervous system. They allow the influx of ions across the membrane once the neurotransmitter binds, allowing the subsequent transmission of electrical excitation across the neurons. Other ligand-gated ion channels, like the γ-aminobutyric acid (GABA) receptor, permit anions like chloride into the cells on the binding of the GABA molecule. Their entry into the cell...
Drugs Acting on Autonomic Ganglia: Blockers01:28

Drugs Acting on Autonomic Ganglia: Blockers

Ganglionic blockers inhibit autonomic activity by blocking nicotinic receptors in the autonomic ganglia, suppressing impulse transmission. These blockers lack selectivity between sympathetic and parasympathetic ganglia and are ineffective as neuromuscular junction antagonists. They can be categorized into two groups:
Nondepolarizing (Competitive) Neuromuscular Blockers: Mechanism of Action01:17

Nondepolarizing (Competitive) Neuromuscular Blockers: Mechanism of Action

Nondepolarizing neuromuscular blockers induce paralysis by competitively blocking nicotinic acetylcholine receptors at the muscle end plate. Examples include pancuronium, mivacurium, vecuronium, and rocuronium. These quaternary ammonium derivatives are administered intravenously, are poorly absorbed, and are excreted via the kidneys.
Competitive antagonists prevent acetylcholine from binding to its receptor, inhibiting membrane depolarization. Without conformational changes or intrinsic...
Nondepolarizing (Competitive) Neuromuscular Blockers: Pharmacological Actions01:27

Nondepolarizing (Competitive) Neuromuscular Blockers: Pharmacological Actions

Nondepolarizing neuromuscular blockers prevent the membrane depolarization of muscle cells and inhibit muscle contraction. These are usually administered with anesthetics to achieve complete muscle relaxation. Upon administration, these drugs first block the small, rapidly contracting muscles of the face and hands, followed by the larger muscles of the trunk and the intercostal muscles. The diaphragm is the last muscle to be affected.
Although all competitive neuromuscular blockers are designed...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A myoneural actuator with engineered biophysics for implantable biohybrid systems.

Nature communications·2026
Same author

Design and evaluation of a bone-anchored, neurally-controlled knee prosthesis.

Journal of neuroengineering and rehabilitation·2026
Same author

Human Implementation of Upper Extremity Amputation Incorporating Agonist-Antagonist Myoneural Interface Construction.

Plastic and reconstructive surgery·2025
Same author

Continuous neural control of a 2-DOF ankle-foot prosthesis enables dynamic obstacle maneuvers after transtibial amputation.

medRxiv : the preprint server for health sciences·2025
Same author

MRI Safety Considerations for Permanent Magnet Implants in Muscle.

Journal of magnetic resonance imaging : JMRI·2025
Same author

Biophysical Models With Adaptive Online Learning for Direct Neural Control of Prostheses.

IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society·2025
Same journal

Analysis of End-Tidal CO2 Variability During Plateau Waves Episodes: An Information Theoretic Approach<sup></sup>.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

AI and Tomosynthesis for Breast Cancer Molecular Subtyping: A step toward precision medicine<sup></sup>.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

Towards Sustainable Protein Recovery from Biological Waste: Assessing Polyethersulfone-based Microfiltration.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

Analysis of the cardiovascular response to standardized polymicrobial peritonitis experimental model.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

Automated Wrist Ultrasound Image Bone Enhancement and Segmentation Using Deep Learning.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

A Deep Learning approach for Depressive Symptoms assessment in Parkinson's disease patients using facial videos.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
See all related articles

Related Experiment Video

Updated: Jun 2, 2026

An Implantable System For Chronic In Vivo Electromyography
09:52

An Implantable System For Chronic In Vivo Electromyography

Published on: April 21, 2020

10.6K

Compact Reversible Nerve Block System for Wearable Bioelectronics.

Seong Ho Yeon, Christian Landis, Guillermo Herrera-Arcos

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
    |March 5, 2025
    PubMed
    Summary
    This summary is machine-generated.

    Researchers developed a compact hardware system for reversible electrical nerve block, advancing bioelectronics. This new tool aids in studying neural circuits and neurological diseases, with potential for wearable clinical applications.

    More Related Videos

    Implantation and Control of Wireless, Battery-free Systems for Peripheral Nerve Interfacing
    07:13

    Implantation and Control of Wireless, Battery-free Systems for Peripheral Nerve Interfacing

    Published on: October 20, 2021

    3.1K
    A Real-Time Wearable Electromyography Measurement System for Small Animals
    05:00

    A Real-Time Wearable Electromyography Measurement System for Small Animals

    Published on: November 15, 2024

    523

    Related Experiment Videos

    Last Updated: Jun 2, 2026

    An Implantable System For Chronic In Vivo Electromyography
    09:52

    An Implantable System For Chronic In Vivo Electromyography

    Published on: April 21, 2020

    10.6K
    Implantation and Control of Wireless, Battery-free Systems for Peripheral Nerve Interfacing
    07:13

    Implantation and Control of Wireless, Battery-free Systems for Peripheral Nerve Interfacing

    Published on: October 20, 2021

    3.1K
    A Real-Time Wearable Electromyography Measurement System for Small Animals
    05:00

    A Real-Time Wearable Electromyography Measurement System for Small Animals

    Published on: November 15, 2024

    523

    Area of Science:

    • Bioelectronics
    • Neuroscience
    • Biomedical Engineering

    Background:

    • Nerve block is crucial for studying neural function and treating neurological disorders.
    • Existing methods for nerve block may lack precision or reversibility.
    • Advancements in bioelectronics offer new possibilities for precise neural interfacing.

    Purpose of the Study:

    • To introduce a novel, compact hardware architecture for reversible electrical nerve block.
    • To evaluate the design principles and performance of the proposed system.
    • To demonstrate the system's utility in both benchtop and in-vivo settings for bioelectronic research.

    Main Methods:

    • Hardware design and fabrication of a compact system for electrical nerve block.
    • Benchtop evaluation of the system's electrical and functional parameters.
    • In-vivo validation using a mouse model to assess nerve block efficacy and reversibility.

    Main Results:

    • Successful implementation of a compact hardware architecture for nerve block.
    • Demonstration of robust and reversible nerve block in benchtop experiments.
    • Validation of the system's effectiveness in achieving reversible nerve block in a live animal model.

    Conclusions:

    • The developed hardware architecture provides a versatile tool for bioelectronic research.
    • This system facilitates the study of neurological diseases and neural circuitry.
    • The technology holds promise for future wearable clinical interventions.