Metabolomic Analysis of Rat Brain by High Resolution Nuclear Magnetic Resonance Spectroscopy of Tissue Extracts
Published on: September 21, 2014
Spline Baseline Model Flexibility Independently Affects the Accuracy and Precision of In Vivo Proton Magnetic
Kelley M Swanberg1, Martin Gajdošík1, Karl Landheer1
1Department of Biomedical Engineering, Columbia University Fu Foundation School of Engineering and Applied Science, New York, New York, USA.
Abstract:
In vivo proton magnetic resonance spectroscopy (1H-MRS) data often exhibit baselines or low-amplitude signal variations resulting from residual water, imperfectly suppressed lipids, low-amplitude metabolites not considered for fitting, and other features not represented in a basis set. While multitudinous approaches exist to model these baselines in 1H-MR spectral analysis, many continue to lack systematic validation against varied and realistic ground-truth standards. Here, we compare the accuracy (error mean) and precision (error standard deviation) of metabolite scaling estimates by linear combination modeling (LCM) spectral fitting accounting for spectral baselines via smoothed cubic splines at 50 different combinations of fixed knot interval and smoothing weight, either with or without additionally simulated Gaussian basis signals to separately model spectral macromolecules. Synthesized in-vivo-like metabolite brain spectra incorporating macromolecule signals measured using double-inversion-recovery-prepared sLASER (TE 20.1 ms; TR 2 s; TI1 920 ms; TI2 330 ms) at 3 T from single voxels in the frontal and occipital cortex of 10 healthy volunteers (five female; 23 ± 5 y.o.) provided both in vivo realism and a standard ground truth for error calculation. Optimal baseline flexibility differed both by definition of "optimum" as either accuracy or precision and by metabolite. Regardless of definition or metabolite, optimal models were not those yielding the smallest fit residuals. Optimized spline baseline definitions yielded high accuracies (lowest mean error -0.003 ± 2.1% for total N-acetyl aspartate and highest mean error 10.1 ± 19.2% for glutamate + glutamine within fits including macromolecule bases) as well as comparable precision for most metabolites to fits achieved in LCModel; inclusion of simulated macromolecules in baseline models improved maximum fit precision but not accuracy. Taken together, these data illustrate that optimized spline baseline model flexibility exhibits metabolite-specific relationships with 1H-MR spectral quantification accuracy or precision not readily predicted by visual inspection of associated fit residuals and not necessarily improved by adaptive relative to absolute constraints.
More Related Videos
13:56The Use of Magnetic Resonance Spectroscopy as a Tool for the Measurement of Bi-hemispheric Transcranial Electric Stimulation Effects on Primary Motor Cortex Metabolism
Published on: November 19, 2014
09:30Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
Published on: December 18, 2016
Related Concept Videos
NMR Spectrometers: Resolution and Error Correction
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
NMR Spectroscopy: Chemical Shift Overview
For instance, the proton...
¹H NMR: Complex Splitting
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied...
Proton (¹H) NMR: Chemical Shift
Absorption signals of all the protium nuclei...
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution