Imaging small dynamic lesions using positron emission tomography and computed tomography: an 18F-sodium fluoride
Anna K Barton1,2, Jacek Kwiecinski1,3, Hidenobu Hashimoto1
1Departments of Medicine (Division of Artificial Intelligence in Medicine) and Biomedical Sciences, Cedars-Sinai Medical Center, 6500 Wilshire Blvd, Los Angeles, CA 90048, USA.
Aims:
18F-sodium fluoride (18F-NaF) positron emission tomography (PET) detects active microcalcification and predicts adverse outcomes including bioprosthetic valve deterioration. However, measuring small areas of 18F-NaF uptake within moving structures remains challenging, requiring further optimization. We developed a representative cardiac phantom to optimize 18F-NaF imaging of bioprosthetic valves.
Methods And Results:
We placed a bioprosthetic valve with two pockets sutured to the leaflets mimicking valvular lesions and a subvalvular ring mimicking the valve remnant into the phantom and injected each with 18F-radionuclide (1 μCi pockets, 4 μCi ring). We injected the cardiac chambers with iohexol and 18F-radionuclide (0.176 mCi) for background activity. PET and computed tomography (CT) images were acquired using a Siemens Biograph Vision high-resolution digital PET/CT scanner. We analysed target-to-background ratio (TBR) and signal-to-noise ratio (SNR) and subjective measures of image quality. We compared results with a human case of transcatheter aortic valve replacement. Initially the SNR and TBR in the phantom greatly exceeded those from human imaging. We reduced the scan duration used for reconstruction to 30 and 15 s, achieving comparable results (30 s vs. 15 s vs. patient: SNR 45.6 vs. 13.9 vs. 44.3, TBRmax 6.5 vs. 5.4 vs. 4.1, noise 10.2% vs. 8.8% vs. 12.0%). With motion correction, SNR and image quality improved in the phantom (30 s 135.8 vs. 45.6, 15 s 32.9 vs. 13.9) but remained similar in the human case (47.3 vs. 44.3).
Conclusion:
A cardiac phantom can mimic clinical 18F-NaF valve bioprosthesis imaging, providing an opportunity to explore acquisition, reconstruction, and post-processing of 18F-NaF PET/CT for small mobile cardiac structures.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...