Related Experiment Video
Updated: May 2, 2026

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
Published on: June 7, 2015
Independent verification system for intracavitary brachytherapy based on a reference plan and statistical model
Yuichi Akino1, Fumiaki Isohashi1,2, Takehiro Arimura3
1Department of Radiation Oncology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan.
Abstract:
High dose rate (HDR) intracavitary brachytherapy (ICBT) with a remote afterloading system plays a vital role in the treatment of cervical cancer. We aimed to develop a new verification system for ICBT for cervical cancer and evaluate the feasibility for clinical plans (PlanClin) generated for different remote afterloaders, applicators and treatment techniques. In total, 517 PlansClin of patients were treated with Elekta 192Ir microSelectron HDR v2r. Reference plans (PlanRef) were generated for the ICBT applicators. An equation to predict total dwell time (Tdwell) of PlanClin was generated by evaluating the relationship between the volume receiving 100% of the prescribed dose (V100%) and the Tdwell. We also developed software to detect human errors in PlanClin by comparing parameters, including applicator and reference point geometries, dwell position and weight patterns and reference point dose, with those of PlanRef. Feasibility was evaluated for 83 PlanClin cases treated with the Elekta Flexitron remote afterloader and six ICBT plans with extra catheters (hybrid BT). The linear fitting function showed good agreement with the correlation between V100% and Tdwell. The developed equation accurately estimated the Tdwell of the PlanClin treated with the Flexitron with an accuracy of 0.26 ± 0.49%. Our system successfully detected intentional human errors including incorrect channel mapping, applicator tip offset, incorrect plan templates, an applicator digitization model and incorrect reference points. A verification system based on PlanRef and a statistical approach is feasible for the new remote afterloaders, applicators and hybrid BT techniques. This system contributes to the implementation of safe treatments.
Related Concept Videos
Analysis Methods of Pharmacokinetic Data: Model and Model-Independent Approaches
The model approach uses mathematical models to describe changes in drug concentration over time. Pharmacokinetic models help characterize drug behavior in patients, predict drug concentration in the body fluids, calculate optimum dosage regimens, and evaluate the risk of toxicity. However, ensuring that the model fits the experimental data accurately...
Model-Independent Approaches for Pharmacokinetic Data: Noncompartmental Analysis
One important characteristic of noncompartmental analyses is that drug exposure increases proportionally with increasing doses. This...

