A comparative in vitro study on monomer release from flash-free or conventional bonding systems
Baris Can Telatar1, Gul Yildiz Telatar2
1Department of Orthodontics, Faculty of Dentistry, Akdeniz University, Antalya, Turkey.
Clinical Oral Investigations
|March 5, 2025
Summary
Adhesive-precoated flash-free brackets released more residual monomers than traditional adhesives in vitro. Further research is needed to assess potential cytotoxic effects before clinical use.
Area of Science:
- Dental Materials Science
- Biomaterials
- Orthodontic Adhesives
Background:
- Orthodontic bracket debonding involves adhesive remnants.
- Residual monomers from adhesives may pose health risks.
- Flash-free adhesives aim to simplify clinical procedures.
Purpose of the Study:
- To quantify and compare residual monomer release from adhesive-precoated flash-free brackets versus traditional light-cure and chemical-cure adhesives.
- To identify specific monomers released by each adhesive system.
Main Methods:
- Sixty stainless steel brackets were bonded using three adhesive systems: adhesive-precoated flash-free, Transbond XT (light-cure), and a chemical-cure system.
- Liquid samples were collected at 1, 7, 21, and 35 days post-bonding.
- Residual monomer elution was analyzed using liquid chromatography.
Main Results:
- All tested adhesives released urethane dimethacrylate, triethylene glycol dimethacrylate, hydroxyethyl methacrylate, and Bisphenol A-glycidyl methacrylate.
- The adhesive-precoated flash-free system showed higher total monomer release (excluding hydroxyethyl methacrylate) compared to the other groups.
- The chemical-cure group exhibited the highest hydroxyethyl methacrylate release.
Conclusions:
- The adhesive-precoated flash-free system demonstrated the highest release of residual monomers in this in vitro study.
- Potential cytotoxic effects of the adhesive-precoated flash-free system warrant further investigation.
- This study is the first to evaluate monomer release from adhesive-precoated flash-free brackets, highlighting differences due to bracket base design and chemical composition.
More Related Videos
Related Concept Videos
Bonding and Strength of Aggregate
The bond between aggregate particles and the cement matrix is significantly influenced by the shape and surface texture of the aggregates. High-strength concretes benefit from a rougher texture, which leads to stronger bonding due to greater adhesion. Angular aggregates with larger surface areas also enhance this bond. The bonding quality, however, is complex to assess as no universally accepted test exists. Good bonding is indicated when a crushed concrete specimen shows some aggregate...
In Vitro Drug Dissolution: Alternative Methods
Alternative drug dissolution methods include the rotating bottle, intrinsic dissolution test, peristalsis, and the Franz diffusion cell method. The rotating bottle method involves meticulously rotating tightly capped controlled-release beads in a temperature-controlled bath. Periodic decanting of samples allows for residue assay, followed by refilling with fresh medium and testing at various pH levels to emulate the gastrointestinal tract conditions.In contrast, the intrinsic dissolution test...