Related Experiment Video
Updated: Jul 21, 2026

An Anesthesia, Surgery, and Harvest Method for the Evaluation of Transpedicular Screws Using an In Vivo Porcine Lumbar Spine Model
Published on: May 31, 2017
Serum Titanium Levels Remain Elevated 6 Years and Beyond From Spinal Instrumentation in Children
Peter J Cundy1, Georgia Antoniou2, Jennie Louise3
1Women's & Children's Hospital, University of Adelaide.
Background:
Paediatric spinal implants are known to cause circulating metal ions. A previous prospective study by the authors demonstrated elevated chromium, cobalt, nickel, and especially persistence of titanium serum levels at a median of 5.4 times baseline level.
Methods:
A continuation of prospective study of children undergoing spinal deformity surgery with repeated testing for circulating metal ions including preoperative levels as controls. Thirty-four of 56 participants returned beyond 6 years from surgery for testing for circulating metal ions using high-resolution inductively coupled plasma mass spectrometry. Linear mixed effects models adjusting for repeated measurements over time were used to analyse titanium, chromium, cobalt, and nickel serum levels.
Results:
Median titanium levels at 6 years decreased significantly to 0.46 times that of 2-year levels (95% CI: 0.32-0.67, P <0.001); however, they remained 2.40 times higher compared with the presurgery control levels (95% CI: 1.47-3.92, P <0.001). In comparison, median chromium levels at 6 years were significantly increased from 2 years (1.45 times) but were not significantly different to baseline (1.13 times). Cobalt levels at 6 years remained significantly higher than baseline (1.32 times), but also decreased significantly compared with 2-year levels (0.76 times). Nickel levels at 6 years did not differ significantly from baseline or from 2-year levels.
Conclusions:
Titanium remains raised at beyond 6 years from spinal instrumentation in children. The effects on a person's health through deposition in solid organs including the brain or on the offspring of persons with spinal instrumentation remains unclear. Curiously, chromium levels increased at 6-year sampling in "all titanium" constructs which may be explained by metallurgical irregularities.
Level Of Evidence:
Level II.
Related Concept Videos
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure in the Leg
Preparation:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure