Quantitative Static and Dynamic Assessment of Balance Control in Stroke Patients
Published on: May 17, 2020
Reliability of Dynamic Balance Test with A Mobile Application of Physics Toolbox Suite
Erdem Atalay1, Ebru Turan Kızıldoğan2
1Department of Sports Medicine, Faculty of Medicine, Eskisehir Osmangazi University, Eskisehir, Türkiye.
Abstract:
Although mobile applications are used as an alternative to expensive and difficult to access systems used to evaluate dynamic balance, existing applications have some shortcomings. This study aimed to evaluate the reliability of the Physics Toolbox Suite mobile application, which can obtain objective data for dynamic balance measurements in healthy adults, shorten the duration of measurements, and minimize the number of measurement equipment. The dynamic balance of 22 university students (9 male, 13 female, aged 20.3 (± 1.13 years)) was evaluated using the Physics Toolbox Suite mobile application in three test sessions with a 1-week interval. Anterior-posterior stability index (APSI), medial-lateral stability index (MLS), and overall stability index (OSI) of dynamic balance were calculated. Interclass Correlation Coefficients (ICC), Minimal Detectable Change (MDC), Standard Error of Measurement (SEM), and Coefficient of Variation for SEM (CVSEM) were evaluated as indicators of intra- and inter-rater reliability. The mean APSI, MLSI, and OSI scores (Standard deviation) were 2.59 (0.69), 2.21 (0.68), and 3.58 (0.94), respectively. In the evaluation made with the Physics Toolbox Suite mobile application, APSI scores had good intra-rater (ICC(3,1) = 0.67) and inter-rater reliability (ICC(3,1) = 0.73), MLSI scores had high intra-rater (ICC(3,1) = 0.90) with good inter-rater reliability (ICC(3,1) = 0.71), and OSI scores had high intra- rater (ICC(3,1) = 0.87) with good inter-rater reliability (ICC(3,1) = 0.73). The Physics Toolbox Suite Mobile Application can be used as a reliable objective tool to assess dynamic balance among healthcare professionals and athletes.
Related Concept Videos
Rigid Body Equilibrium Problems - II
Consider two children sitting on a seesaw, which has negligible mass. The first child has a mass (m1) of 26 kg and sits at point A, which is 1.6 meters (r1) from the pivot point B; the second child has a mass (m2) of 32 kg and sits at point C. How far from the pivot point B should the second child sit (r2) to balance the seesaw?
Static Equilibrium - I
Static Equilibrium - II
Rigid Body Equilibrium Problems - I
Measuring Acceleration Due to Gravity
A simple pendulum can be described as a point mass and a string. Meanwhile, a physical pendulum is any object whose oscillations are similar to a simple pendulum, but cannot be modeled as a point mass on a string because its mass is distributed over a larger area. The behavior of a physical pendulum can be modeled using the principles of...
Stability of Equilibrium Configuration: Problem Solving
Problem-solving in the context of the stability of equilibrium configuration...