Multidimensional-Constrained Suspect Screening of Hydrophobic Contaminants Using Gas Chromatography-Atmospheric
Xiaodi Shi1, Anna Sobek1, Jonathan P Benskin1
1Department of Environmental Science, Stockholm University, Stockholm 10691, Sweden.
Abstract:
Suspect screening strives to rapidly monitor a large number of substances in a sample using mass spectral libraries. For hydrophobic organic contaminants (HOCs), these libraries are traditionally based on electron ionization mass spectra. However, with the growing use of state-of-the-art mass spectrometers, which often use alternative ionization approaches and separation techniques, new suspect screening workflows and libraries are urgently needed. This study established a new suspect screening library for 1,590 HOCs, including exact mass and a combination of measured and model-predicted values for retention time (RT) and collision cross section (CCS). The accuracy of in silico predictions was assessed using standards for 102 HOCs. Thereafter, using gas chromatography-atmospheric pressure chemical ionization-ion mobility-mass spectrometry, a suspect screening workflow constrained by the full scan mass spectrum of (quasi-)molecular ions (including isotope patterns), RT, CCS, and fragmentation mass spectra, together with a continuous scoring system, was established to reduce false positives and improve identification confidence. Application of the method to fortified and standard reference sediment samples demonstrated true positive rates of 79% and 64%, respectively, with all false positives attributed to suspect isomers. This study offers a new workflow for improved suspect screening of HOCs using multidimensional information and highlights the need to enrich mass spectral databases and extend the applicable chemical space of current in silico tools to hydrophobic substances.
More Related Videos
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...