Related Experiment Video
Updated: Aug 11, 2026

A Swine Model of Neonatal Asphyxia
Published on: October 11, 2011
Maternal, fetal, and newborn tissue PO2 in sheep measured with galvanic oxygen electrodes
Abstract:
Tissue PO2 was measured with galvanic oxygen electrodes chronically implanted in maternal and fetal tissues of two pregnant ewes. Labor commenced after 3 days in one ewe and after 11 days in the other. Tissue PO2 was measured in both newborn lambs. Fetal tissue PO2 during labor was less than 3 mm Hg but rose to values similar to those found in adult tissues in the newborn period. Function of the electrode and response of the tissue to change in oxygenation was challenged by administration of 100% oxygen to the pregnant ewe or newborn lamb, and by administration of intravenous epinephrine to the ewe. These tests suggested that all electrodes were functioning satisfactorily in vivo and that tissue PO2 was responding as anticipated. Recalibration of electrodes after removal from the tissues confirmed that their response in vitro was similar to that obtained before implantation.
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...