Related Experiment Video
Updated: May 24, 2025

An Automated Microscopic Scoring Method for the γ-H2AX Foci Assay in Human Peripheral Blood Lymphocytes
Published on: December 25, 2021
Calculations of Mean Quality Factors and Their Implications for Organ-specific Relative Biological Effectiveness
Shota Shimizu1, Tatsuhiko Sato2, Sachiyo Funamoto1
1Department of Statistics, Radiation Effects Research Foundation, Hiroshima, Japan.
Abstract:
Past and current estimates of relative biological effectiveness (RBE) from the cohort analyses of atomic bomb survivors suggested not only that RBE may be much higher than those assessed by the United Nations Scientific Committee on Effects of Atomic Radiation (UNSCEAR) and International Commission on Radiological Protection (ICRP), but also that RBE may differ by organ and organ depth. This is at least partly due to how the ratio of neutron to gamma-ray dose changes with organ depth because of the more rapid attenuation of neutrons in tissue. Additionally, the RBE estimates from Life Span Study (LSS) data depend on the total dose and the neutron/gamma ratio. To further examine this issue, we calculated the mean quality factor based on Linear Energy Transfer (LET) distributions for representative organs and exposure scenarios of A-bomb survivors using Particle and Heavy Ion Transport code System (PHITS) simulation and the radiation quality factor [Q(L) relationship] defined by ICRP, as well as the Quality Factor (QF) function defined by the National Aeronautics and Space Administration (NASA). This is done in the context of the adult male phantom of the J45 series, which was created to precisely reproduce the anatomy of the Japanese population in 1945. We also investigate the depth dependence of the mean quality factors in the International Commission on Radiation Units and Measurements (ICRU) sphere irradiated by mono-energetic neutrons. Both the results from the human phantom, and from the ICRU sphere phantom suggest that the mean quality factors are approximately 15 and independent of the organ type, body depth, city and ground range when the contributions from the secondary γ rays are excluded from the neutron doses. We also discuss reasons that RBE estimates from cohort analyses are generally much larger than those based on the mean quality factors.
More Related Videos
Related Concept Videos
Biological Effects of Radiation
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Relative Risk
Actuarial Approach
Consider the example of a high-risk surgical procedure with significant early-stage mortality. A two-year clinical study is conducted,...

