Influence of HeartMate 3™ on Bispectral Index™ monitor: a retrospective observational study
Seiichi Azuma1,2, Masaaki Asamoto3, Shinichi Akabane1,2
1Department of Anesthesiology and Pain Relief Center, The University of Tokyo Hospital, Hongo 7-3-1, Bunkyo-ku, Tokyo, 113-8655, Japan.
Abstract:
Electroencephalogram-derived monitors are affected by various artifacts. HeartMate 3™ operates at frequency bands that overlap with those used for calculating the electromyographic index (EMG) and bispectral index (BIS) on the Bispectral Index™ monitor. This study investigated whether HeartMate 3 elevates these values, a change not predicted with HeartMate II™. This retrospective observational study included data from patients who underwent HeartMate 3 or II implantation between April 2008 and December 2023 as extracted from our institutional database. Patient-wise median EMG and BIS were compared between the pre-LVAD period (from the start of surgery to initiation of cardiopulmonary bypass) and the post-LVAD period (from the end of cardiopulmonary bypass to end of surgery). Data were obtained from 33 and 43 patients who underwent HeartMate 3 and HeartMate II implantation, respectively. Patients with HeartMate 3 implantation showed significant elevation in the EMG (pre-LVAD, mean ± standard deviation, 26.1 ± 1.0 dB; post-LVAD, 39.5 ± 2.8 dB; P < 0.001) without a significant change in the BIS (pre-LVAD, 44.5 ± 8.1; post-LVAD, 45.5 ± 7.1; P = 0.35). In contrast, patients with HeartMate II implantation did not show significant changes in either the EMG (pre-LVAD, 26.1 ± 1.2 dB; post-LVAD, 27.1 ± 4.1 dB; P = 0.16) or BIS (pre-LVAD, 45.1 ± 9.2; post-LVAD, 43.0 ± 8.1; P = 0.071). HeartMate 3 significantly elevates EMG. Anesthesiologists should be aware of this to appropriately interpret EMG elevation in patients with HeartMate 3.Trial registration: Japan Registry for Clinical Trials identifier: jRCT1030230549 (date of registration: January 10, 2024.
More Related Videos
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
08:22Author Spotlight: Advancing the Study of Brain-Heart Interplay with a Comprehensive EEGLAB Plugin for Multimodal Signal Analysis
Published on: April 26, 2024
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...