Background:
Laboratory reagents impact measured factor activity of extended half-life (EHL) concentrates. Variability in measurements may lead to under or over estimation of the pharmacokinetic (PK) parameters, and thus influence clinical dosing decisions. Since 2020, WAPPS-Hemo (www.wapps-hemo.org) has been collecting reagent information when haemophilia centres submit data for PK parameters estimation.
Objectives:
To identify the pairs of concentrates (recombinant FVIII and FIX) and reagents leading to significant discrepancies between observed PK estimates compared to WAPPS-Hemo population.
Methods:
PK data were extracted from the WAPPS-Hemo database. PK estimates were obtained using WAPPS-Hemo Bayesian engine and analysis was reported for terminal half-life and time to 3% following a 50 IU/kg infusion. Log-deviations between individual PK estimates and WAPPS-Hemo population PK models typical values were calculated to remove known sources of variability. Multivariate analysis of variance (MANOVA) regression was performed to assess the reagent effects.
Results:
A total of 3853 and 1312 PK estimates were used to analyse reagent effects on the four FVIII and three FIX EHL concentrates, respectively. The reagent was not provided for 2391 PK estimates (46.3%). WFH unadvised reagents were provided for 78 PK estimates only (2.8% of known reagents). For each concentrate/reagent pair recommended by WFH, no significant difference was identified, except for rFIX-Fc whose PK parameters were significantly and clinically under-estimated by STA PTT-A.
Discussion/Conclusion:
Real-world data provided by haemophilia centres showed high congruence with WFH guidelines, although its sizable number not declaring reagent. WFH-recommended reagents did not significantly impact PK estimation. For rFVIII-PEG, reagents also did not impact PK estimation. Although usually not enough data were available to assess reagents that were unadvised by WFH.
More Related Videos
13:57Bio-layer Interferometry for Measuring Kinetics of Protein-protein Interactions and Allosteric Ligand Effects
Published on: February 18, 2014
10:16Autoradiography as a Simple and Powerful Method for Visualization and Characterization of Pharmacological Targets
Published on: March 12, 2019
Related Concept Videos
Drug Concentrations: Measurements
Plasma...
Nonlinear Pharmacokinetics: Role of Transporters
Polymorphisms occurring in drug transporters can alter...
Nonlinear Pharmacokinetics: Bioavailability and Protein-Drug Binding
To quantify the extent of bioavailability, pharmacologists often use a parameter called .
Nonlinear Pharmacokinetics: Overview
Nonlinearity can arise due to the saturation of plasma protein-binding or...
Nonlinear Pharmacokinetics: Causes of Nonlinearity
Nonlinear drug absorption can occur when the process is rate-limited by solubility, carrier-mediated transport systems, or saturation of the presystemic gut wall or hepatic metabolism. For instance, high doses of riboflavin...
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...