Pressure-Tunable Photoionization Tandem Ion Mobility Spectrometry for Investigating Proton Transfer Reactions of
Yiqian Xu1,2,3, Qimu Yang1,2,3, Yi Yu1,3
1State Key Laboratory of Medical Proteomics, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, People's Republic of China.
Abstract:
Investigating and manipulating the ion-molecule reactions within the ionization source of ion mobility spectrometry (IMS) or mass spectrometry can contribute to developing advanced ionization sources and novel analytical techniques. In this study, a pressure-tunable photoionization tandem ion mobility spectrometer (PI-tandem-IMS) was developed to investigate the ionization suppression caused by unusual proton transfer reactions in dual-analyte systems in which high proton affinity (PA) ions are deprotonated by low PA molecules. The proton transfer reaction mechanisms in the toluene-acetone and toluene-ethanol systems were studied. The experimental results showed the linear correlation between the ln(SX2H+·K0(T+)/ST+·K0(X2H+) + 1) and the square of the reactant concentration cX2, as well as the cubic power of the pressure p3. Based on this, the generation of the proton-bound dimers in the toluene-acetone and toluene-ethanol systems was assigned as a termolecular process. The reaction rate coefficients k of the toluene-acetone and toluene-ethanol systems were calculated at different temperatures, and the Arrhenius plot showed that rate coefficients were both negatively correlated with temperature, implying that elevated temperatures suppress the proton transfer reaction. At 313.15 K, the calculated k values for the toluene-acetone and the toluene-ethanol systems were 2.2 × 10-26 cm6/s and 5.2 × 10-28 cm6/s, respectively, suggesting a higher inhibitory effect of acetone on toluene ionization than that of ethanol. Besides, the suppressive effect of reducing the pressure or increasing the reaction region electric field strength on proton transfer reactions was shown, which demonstrated the PI-tandem IMS was a good tool for understanding ion-molecule reactions in the ionization source.
More Related Videos
16:40T-wave Ion Mobility-mass Spectrometry: Basic Experimental Procedures for Protein Complex Analysis
Published on: July 31, 2010
10:03Proton Transfer and Protein Conformation Dynamics in Photosensitive Proteins by Time-resolved Step-scan Fourier-transform Infrared Spectroscopy
Published on: June 27, 2014
Related Concept Videos
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Chemical Ionization (CI) Mass Spectrometry
Mass Analyzers: Common Types
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...