Related Experiment Video
Updated: May 23, 2025

Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
Sepsis-Extracorporeal Membrane Oxygenation Score in Patients Receiving Extracorporeal Membrane Oxygenation Support
Hongfu Fu1, Liangshan Wang, Yan Wang
1From the Center for Cardiac Intensive Care, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Abstract:
Predictive scoring systems for adult patients receiving extracorporeal membrane oxygenation (ECMO) support for sepsis have not been yet reported. Based on the Chinese Society of ExtraCorporeal Life Support (CSECLS) Registry database, we conducted a retrospective observational study on adult patients supported with ECMO for sepsis (n = 465). On the basis of multivariable logistic regression analyses, four parameters at 24 h post-ECMO initiation ( T24 ) were identified as prognostic factors associated with in-hospital mortality: age, vasoactive inotropic score (VIS), partial pressure of oxygen in arterial blood (PaO 2 ), and lactate clearance. The sepsis-ECMO score was calculated based on these prognostic factors, which were converted into categorical variables. The area under the receiver operating characteristic curve for the sepsis-ECMO score was 0.704 (95% confidence interval [CI]: 0.658-0.751). Four risk classes, namely class Ⅰ (score 0), class Ⅱ (score 5), class Ⅲ (score 6-10), and class Ⅳ (score ≥ 11), were identified according to sepsis-ECMO score quartiles. Patients in the lower sepsis-ECMO score classes had significantly better survival than those in the higher classes (log-rank test, p < 0.001). The sepsis-ECMO score may help in the risk stratification of patients, facilitate the communication of objective prognostic information, and provide a clearer direction for shared decision-making.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Acute Respiratory Failure-IV
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...

