The Effect of X-ray Dose Photon-Counting Detector Computed Tomography on Nodule Properties in a Lung Cancer Screening
Bjarne Kerber1, Falko Ensle, Jonas Kroschke
1Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, University Zurich, Zurich, Switzerland (B.K., F.E., J.K., R.H., C.B., M.M., T.F., L.J.); Advanced Radiology Center, Department of Diagnostic Imaging and Oncological Radiotherapy, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Rome, Italy (C.S., A.R.L.); and Section of Radiology, Department of Radiological and Hematological Sciences, Università Cattolica del Sacro Cuore Rome, Italy (A.R.L.).
Objectives:
The aim of the study was to evaluate the effect of photon-counting detector (PCD-)CT dose reduction to x-ray equivalent levels on nodule detection, diameter, volume, and density compared to a low-dose reference standard using semiautomated and manual methods.
Materials And Methods:
Between February and July 2023, 101 prospectively enrolled participants underwent noncontrast same-study low- and chest x-ray-dose CT scans using PCD-CT. Patients who were not referred for lung cancer screening or nodule follow-up, as well as those with nodules smaller than 5 mm in diameter, were excluded. Nodule detection and measurement of nodule diameters and volumes was semiautomatically performed for low- and x-ray-dose scans using computer-aided diagnosis software. Additionally, 2 blinded readers manually measured largest nodule diameters and examined nodule density. Nodules were classified using Lung-RADS v2022. Image quality was assessed with subjective and objective measures.
Results:
Mean CTDIvol for x-ray dose scans was 0.11 ± 0.03 mGy, compared to 0.65 ± 0.15 mGy for low-dose images ( P < 0.001). One hundred seventy-two nodules larger than 5 mm were detected in 53 of the 101 participants (32 male, 61.6 ± 12.5 years; 21 female, 60.3 ± 12.5 years). The semiautomated method had high overall sensitivity for nodule detection (0.94) on x-ray dose scans, with a higher sensitivity for solid nodules (>0.95) and lower for subsolid nodules (>0.86). Nodules not detected on x-ray dose scans were significantly smaller. Semiautomated measurements underestimated nodule diameter for solid nodules on x-ray dose scans ( P = 0.01), but no significant effect for nodule volume was found ( P = 0.775). Readers rated nodule density less dense on x-ray dose scans (R1: P < 0.001, R2: P = 0.006). There was no significant difference in nodule diameter for both readers between scan doses (R1: P = 0.141; R2: P = 0.554). There were good to excellent correlations between semiautomated and reader nodule diameters. Agreement and accuracy between low-dose and x-ray dose Lung-RADS classifications across methods were good (Cohens' к = 0.73, 0.62, 0.76 for semiautomated method, R1 and R2; resp. Accuracy: 0.82, 0.78, 0.85). No Lung-RADS classification changes were observed with semiautomated volumetric measurements of nodules.
Conclusions:
Semiautomated nodule detection is highly sensitive in PCD-CT x-ray dose scans. Semiautomated nodule volume measurement is more robust to image quality changes than nodule diameter. Accurate semiautomated and manual nodule measurements are feasible on x-ray dose scans, but nodule density was in tendency underestimated. Nodule classification using Lung-RADS was shown to be accurate on x-ray dose scans.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
X-ray Imaging
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Biological Effects of Radiation
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...