Related Experiment Video
Updated: May 23, 2025

The Effect of the Application of Thyme Essential Oil on Microbial Load During Meat Drying
Published on: March 14, 2018
Differentiated application of oxygen levels for the preservation of high‑oxygen packaged beef based on initial
Chengcheng Feng1, Kaiyang Sun1, Yimin Zhang2
1Lab of Meat Processing and Quality Control, College of Food Science and Engineering, Shandong Agricultural University, Tai'an 271018, Shandong, PR China.
Abstract:
This study investigated the influence of various oxygen (O2) levels on the storage quality of chilled beef steaks with different initial microbial loads (low initial microbial loads, LIML; high initial microbial loads, HIML). The steaks were stored under three modified atmosphere packaging (MAP) systems (MAP70 = 70 % O2/30 % CO2; MAP50 = 50 % O2/30 % CO2/20 % N2; MAP30 = 30 % O2/30 % CO2/40 % N2) for 20 days. Oxygen levels had no impact on bacterial counts and microbial diversity during storage, in which Serratia and Brochothrix became predominant bacteria. No differences in a*, b*, chroma, and sensorial traits were observed for LIML steaks under the three MAP systems, but MAP30 steaks showed the lowest (P < 0.05) lipid and protein oxidation. Compared to MAP70, MAP50 instead of MAP30 was sufficient to maintain a similar meat color and a better oxidative stability for HIML steaks. Overall, microbial proliferation was a significant determinant for the color stability of MAP beef, and therefore the O2 optimization in high‑oxygen MAP should take initial microbial loads into account.
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...

