Related Experiment Video
Updated: Jun 19, 2026

Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
Published on: July 19, 2016
Inflow-to-Outflow Stent Frame Expansion, Ellipticity, and Decoupling in Evolut TAVR: Implications for Mid-term
Rishi Puri1, Julianne Spencer2, Didier Tchétché3
1Heart, Vascular & Thoracic Institute, Cleveland Clinic, Ohio.
Background:
The native aortic annulus for self-expanding transcatheter aortic valve replacement (TAVR) has variable ellipticity. A noncircular and underexpanded transcatheter aortic valve (TAV) may impact hemodynamic performance. This study aimed to quantify Evolut TAV (Medtronic) frame ellipticity and expansion 30 days post-TAVR and evaluate their impact on 1-year hypoattenuating leaflet thickening and 4-year hemodynamics.
Methods:
We retrospectively evaluated 184 patients from the Evolut Low Risk substudy with high-quality computed tomography images. Frame ellipticity ratio and percent expansion were quantified at each frame node level 30 days after TAVR. Variables associated with frame deformation, 1-year hypoattenuating leaflet thickening, and 4-year hemodynamics were identified.
Results:
Mean Evolut frame ellipticity was highest at the inflow (1.18 ± 0.08) and lowest at the functional leaflet region (1.05 ± 0.03) and frame outflow (1.04 ± 0.03). Frame expansion was lowest at the inflow (83.8% ± 4.9%) and highest at the functional leaflet region (97.8% ± 1.7%). TAV frame circularity and expansion significantly increased from the annular level to the leaflet region (P < .001). Mean gradient, effective orifice area, and paravalvular regurgitation at 4 years were not affected by Evolut TAV's relative noncircularity and underexpansion at the frame inflow. Frame underexpansion at the leaflet region, however, was associated with a smaller effective orifice area at 4 years.
Conclusions:
Evolut frame deformation at the inflow did not affect the circularity and expansion of the stent at the functional leaflet region. Mid-term (4-year) Evolut hemodynamic performance does not appear to be impacted by frame inflow geometry.
Related Concept Videos
Blood Flow
Accelerating Fluids
The motion of the liquid within this infinitesimal cylinder is considered to obtain the pressure difference. Three vertical forces act on this liquid:
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Development of Blood Vessels
The initial formation of this system is facilitated by the small amount of yolk present in the ovum and yolk sac. Blood vessels originate from...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Turbulent Flow