Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

4.9K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
4.9K
Imaging Studies I: CT and MRI01:14

Imaging Studies I: CT and MRI

164
Introduction: MRI and CT scans are crucial advancements in medical imaging techniques, playing a vital role in diagnosing conditions related to the gastrointestinal (GI) system. Each scan serves distinct purposes, targets specific areas, and requires unique nursing duties.
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
164

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Clinicopathologic features and results of transcatheter arterial chemoembolization for osteosarcoma.

Cardiovascular and interventional radiology·2007
Same author

[The clinical significance of expression and amplification of FGF3 in bladder transitional cell carcinoma].

Zhonghua yi xue za zhi·2007
Same author

Efficient in vivo 31P magnetization transfer approach for noninvasively determining multiple kinetic parameters and metabolic fluxes of ATP metabolism in the human brain.

Magnetic resonance in medicine·2006
Same author

Tuning the hole injection barrier at the organic/metal interface with self-assembled functionalized aromatic thiols.

The journal of physical chemistry. B·2006
Same author

Mutation screening of brain-expressed X-chromosomal miRNA genes in 464 patients with nonsyndromic X-linked mental retardation.

European journal of human genetics : EJHG·2006
Same author

[Characterization of hydrogen peroxide production by a novel oral streptococci, S. oligofermentans isolated from human oral cavity].

Wei sheng wu xue bao = Acta microbiologica Sinica·2006

Related Experiment Video

Updated: May 23, 2025

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
09:30

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease

Published on: December 18, 2016

19.3K

Optimizing knee joint imaging: A comparative study of 7T MRI sequences.

Xiaoqi Yi1, Zhiming Zhen1, Xiaoli Gou2

  • 17T Magnetic Resonance Translational Medicine Research Center, Department of Radiology, Southwest Hospital, Army Medical University (Third Military Medical University), No. 30 Gaotanyan Main Street, Chongqing 400038, China.

Magnetic Resonance Imaging
|March 10, 2025
PubMed
Summary

Optimizing 7 Tesla MRI for knee joints involves comparing proton density fat-saturated (PD-FS) and 3D double-echo steady-state (3D-DESS) sequences. A combined approach offers comprehensive visualization and patient comfort.

Keywords:
3D double-Echo steady stateContrast-to-noise ratioKnee jointProton density fatSaturatedSusceptibility-weighted imagingUltra-high-field MRI

More Related Videos

Author Spotlight: Investigating Early Events and Long-Term Effects of ACL Injuries for Osteoarthritis Progression
06:27

Author Spotlight: Investigating Early Events and Long-Term Effects of ACL Injuries for Osteoarthritis Progression

Published on: September 29, 2023

609
Four-Dimensional CT Analysis Using Sequential 3D-3D Registration
05:05

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration

Published on: November 23, 2019

7.8K

Related Experiment Videos

Last Updated: May 23, 2025

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
09:30

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease

Published on: December 18, 2016

19.3K
Author Spotlight: Investigating Early Events and Long-Term Effects of ACL Injuries for Osteoarthritis Progression
06:27

Author Spotlight: Investigating Early Events and Long-Term Effects of ACL Injuries for Osteoarthritis Progression

Published on: September 29, 2023

609
Four-Dimensional CT Analysis Using Sequential 3D-3D Registration
05:05

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration

Published on: November 23, 2019

7.8K

Area of Science:

  • Radiology
  • Medical Imaging
  • Orthopedics

Background:

  • Magnetic Resonance Imaging (MRI) at 7 Tesla (7T) offers enhanced signal-to-noise ratio (SNR) for detailed anatomical visualization.
  • Optimizing MRI sequences is crucial for balancing image quality, scan time, and patient comfort in knee joint imaging.

Purpose of the Study:

  • To evaluate and compare different 7T MRI sequences for knee joint imaging.
  • To identify optimal sequences for reducing scan duration and improving patient experience while maintaining diagnostic image quality.

Main Methods:

  • A prospective study involving healthy participants undergoing knee scans with 7T MRI.
  • Sequences assessed included proton density fat-saturated (PD-FS), 3-dimensional double-echo steady-state (3D-DESS), and susceptibility-weighted imaging (SWI).
  • Quantitative analysis of SNR and contrast-to-noise ratio (CNR) for key knee structures, alongside qualitative assessment of image quality and inter-observer agreement (ICC).

Main Results:

  • 3D-DESS demonstrated superior SNR for cartilage, ligaments, fluid, and meniscus (P < .001).
  • SWI showed the best cartilage visualization (P < .05), while PD-FS provided the highest quality ligament and meniscus images (P < .001).
  • 3D-DESS yielded the highest contrast for joint fluid (P < .001), and PD-FS excelled in cartilage-meniscus contrast (P < .001).

Conclusions:

  • A combination of PD-FS and 3D-DESS sequences is recommended for comprehensive 7T knee MRI.
  • This combined approach ensures detailed visualization of vital knee structures, improving diagnostic accuracy and patient comfort.