Related Experiment Video
Updated: May 23, 2025

Ultrasonography of the Adult Male Urinary Tract for Urinary Functional Testing
Published on: August 14, 2019
Next-generation Solutions: Are Patients Ready for Electronic Artificial Urinary Sphincters for Male Incontinence?
Marc Kidess1, Troya Ivanova1, Julian Hermans1
1Department of Urology, University Hospital of Munich, Munich, Germany.
Background And Objective:
Urology is characterized by continuous innovation. The inception of robot-assisted radical prostatectomy (RP) marked a pivotal technological advance and further advances in digital treatment options for stress urinary incontinence (SUI) are emerging. Our aim was to assess patient willingness to receive an electronic artificial urinary sphincter (eAUS) implant and identify associated concerns.
Methods:
Patients who received a first AUS implant (AMS800 system) for post-RP SUI from March 2013 to December 2023 were included. An anonymous survey was used to collect data on demographics, current AUS satisfaction, daily technology use, interest in an eAUS, and concerns about potential eAUS technical malfunctions. Data were analyzed using SPSS, with significance set at p < 0.05.
Key Findings And Limitations:
Out of 345 patients, 208 (60.2%) completed the questionnaire. The majority were aged 71-80 yr (51.7%) and had a university education (37.7%). Satisfaction with their AUS was high: 79.8% of the respondents were satisfied, 88.9% were satisfied with its handling, and 89.4% would choose an AUS implant again. Notably, 60.4% showed interest in an eAUS, with younger respondents and those who use technology on a daily basis expressing greater interest. Preferred control methods included remote-based (78.4%) and smartphone-based (60.0%) options. Concerns about system malfunction (66.4%), connection loss (65.9%), and battery issues (60.0%) were prevalent.
Conclusions And Clinical Implications:
There was significant patient interest in an eAUS in our survey, especially among younger individuals and those who use technology daily. Despite high satisfaction with current AUS devices, addressing potential technical malfunctions and patient concerns is crucial for broader acceptance of an eAUS. Patient concerns about technological malfunctions seem to outweigh worries about medical issues.
Patient Summary:
Urology is becoming more advanced with technologies like robotic surgery and electronic artificial urinary sphincters (eAUS). According to our survey, most patients are happy with their current sphincters and are open to eAUS, especially younger patients who are familiar with technology. However, patients are concerned about system malfunctions and connection loss. More research is needed to address technical issues and patient concerns.
Related Concept Videos
The Micturition Reflex
The process begins with bladder filling, where the bladder wall stretches as urine accumulates. This stretching activates the urine storage reflex, mediated by the sacral spinal segments and the pontine storage center. Efferent sympathetic impulses stimulate the detrusor muscle to relax and the internal urethral sphincter to contract, facilitating...
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...
Male Sexual Response: Erection & Ejaculation
The blood filling the erectile tissues compresses the veins, which helps to prevent blood from leaving...
Urinary Bladder
In males, the bladder is situated in front of the rectum, while in females, it is positioned anterior to the vagina and uterus. The bladder floor contains an inverted triangular area called the trigone, defined by the two ureteric...
Pre-Procedural Guidelines for Assessing Blood Pressure