Phenolic Preservatives Are Not the Sole Cause of Eosinophilic Infiltration at Infusion Pump Sites
Priscila Silva Cunegundes1, Kenneth Wood1, Li Mao1
1Department of Physiology, Integrative Biosciences Center (IBio), Wayne State University, Detroit, MI, United States.
Abstract:
Background: Skin reactions and discomfort associated with insulin infusion pumps limit user adherence. A recent histopathological study by Kalus et al. (DERMIS study) reported increased eosinophilic infiltration and imputed an inflammatory response to an allergen delivered at the catheter tip. This finding might explain the pruritus reported by pump users. As eosinophils migrate to inflammatory foci, primarily due to IL-5 and CCL11, we aimed to evaluate insulin phenolic preservative (IPP) as a potential allergen in vitro and assess tissue eosinophilic infiltration in vivo. Methods: Histopathological evaluations for eosinophil recruitment were performed over 1 week following IPP infusions in swine tissue. Additional histopathological investigations of eosinophilic infiltration were conducted using three commercial glucose sensors implanted in swine for up to 3 weeks. Results: Eosinophilic infiltration in the dermis and subcutaneous tissue was observed following saline and IPP infusion and at glucose sensor implantation at all time points examined. In vitro studies revealed IPP eosinophil cytotoxicity. However, neither CCL11 nor IL-5 was detected in any of the tested tissue cells after IPP treatment. Conclusion: These findings suggest that IPP is not the only triggering allergen, as IPP did not induce eosinophils in vitro, while glucose sensors also indicated increased eosinophilic infiltration. Therefore, factors other than IPP trigger eosinophil recruitment to insulin infusion pump sets.
More Related Videos
09:57A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
Published on: July 13, 2019
05:52Author Spotlight: Induction of Experimental Endotoxemic Shock in Pigs for Studying Hemodynamic and Respiratory Failure
Published on: December 8, 2023
Related Concept Videos
Hand hygiene
Hand washing...
Prevention of Further Absorption of Poison
Antiasthma Drugs: Mast Cell Stabilizers and Anti-IgE Drugs
Mast cell stabilizers, such as cromolyn (also known as sodium cromoglycate) and nedocromil (Tilade), are effective drugs in asthma management. These stabilizers hinder histamine release by skillfully obstructing the activation of mast cells and other cellular entities. Notably, they navigate this task without...
Parenteral Anesthetics: Overview
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...