Related Experiment Video
Updated: May 23, 2025

Precision of In Vivo Quantitative Tooth Wear Measurement Using Intra-Oral Scans
Published on: July 12, 2022
Comparison of Measurement Methods for Stone Volume Estimation: An In Vitro Study
Felipe Pauchard1,2, Frederic Panthier2,3,4, Catalina Espinoza1
1Urology Department, Hospital Naval Almirante Nef, Viña del Mar, Chile.
Abstract:
Urolithiasis guidelines still rely on the maximum stone diameter to propose treatment strategy, although this measure is known to have many pitfalls. Stone volume (SV) could represent a more accurate measurement, helping to plan the treatment or follow-up. Various methods to measure SV have been proposed. We aimed to compare different methods to estimate SV. Fifteen stones (human and artificial) were assessed. Real SV was measured using the water displacement method. Volume estimation included three diameter-based formulas (Ackerman, 4/3 Pi r3 and r3/2) and two 3D segmentation methods (Horos and Kidney Stone Calculator [KSC]). All measurements were done by a single operator. Spearman correlation test and comparative analyses were conducted between the real and the estimated SV. Compared with real SVs, Ackerman and r3/2 formulas estimated volume accurately in 2/15 (13%) of stones each. No accurate measurement was reported using the sphere formula. KSC did estimate volume accurately in 4/15 (27%) stones compared with the reference SV; Horos did it in 7/15 (47%) stones. Both segmentation methods presented strong correlation coefficients (r = 0.9642 and 0.9659, p < 0.0001), while formula correlation was moderate (r = 0.7531, p < 0.0001). Formulas and segmentation methods for SV estimation resulted in divergent outcomes. Segmentation methods (Horos and KSC) presented higher accuracies in SV estimation, compared with real SV. Formulas were the least accurate.
More Related Videos
Related Concept Videos
Measurement of Air Content in Concrete
The pressure method,...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Quarrying of Stone
One common method involves using a diamond belt saw to cut large blocks from the quarry face. These blocks can be about 50 feet long and 12 feet high. After the initial vertical cut, drilling is performed at the base of the...
Vebe Test
To conduct the test, concrete is placed into the slump cone. The concrete is filled in layers and...
Uncertainty in Measurement: Reading Instruments
Design Example: Measuring Distance Between Two Points with Obstructions