Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
A hemodynamic screening tool for symptomatic internal jugular vein stenosis in J3 segment
Min Li1,2, Xiaogang Gao3, Yaqiong Jia4
1Department of Neurology, Xuanwu Hospital, Capital Medical University, Beijing, China.
None:
ObjectivesThe aim of this study was to formulate an ultrasonic diagnostic criterion for stenosis in the J3 segment of internal jugular vein (IJV) and probe into the effects of stenosis in the J3 segment on intracranial pressure (ICP) and the cerebral drainage pattern.MethodsParticipants who exhibited narrowing in the J3 segment of IJV on neuroimaging and reported symptoms correlated with IJV stenosis (IJVS) were enlisted from Xuanwu Hospital. Clinical data were retrospectively amassed.ResultsA total of 163 subjects including 57 IJVS subjects and 106 control subjects were recruited. We unearthed an inverse relationship between the pressure gradient and the flow velocity. Flow velocity at or below 27.5 cm/s coincided with pressure gradient values of 4 mmHg or greater. There is no significant correlation between IJVS and ICP. Additionally, a linear correlation was identified between the bilateral flow volume in the J3 segment and ICP. Values exceeding 425 mL/min were indicative of intracranial hypertension. There was an increase in diameter, flow volume and flow velocity in the bilateral vertebral veins in participants with IJVS.ConclusionsThe J3 segment of IJV displays right dominance. Stenosis can be deduced when the flow velocity in the J3 segment is at or below 27.5 cm/s. Stenosis in the J3 segment yielded a diminished outflow in the IJV and an augmented outflow in the vertebral veins. When bilateral flow volume in the J3 segment exceeds 425 mL/min, it denotes intracranial hypertension.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Assessment of the Cardiovascular System II: Inspection
Head and Neck