Related Experiment Video
Updated: Jul 9, 2026

Basic Research in Plasma Medicine - A Throughput Approach from Liquids to Cells
Published on: November 17, 2017
Pre-clinical Safety Study of Cold Atmospheric Plasma (CAP) Produced by an Inbuilt CAP Device and ROS Mediated
Ratul Chakraborty1,2, Reetesh Borpatra Gohain2,3, Punam Talukdar3
1Pharmacology and Drug Discovery Research Laboratory, Division of Life Sciences, Institute of Advanced Study in Science and Technology (IASST), Vigyan Path, Guwahati, PIN-781035 Assam, India.
Introduction:
In recent decades, Cold Atmospheric Plasma (CAP) has become increasingly popular in healthcare for managing diseases, especially skin cancer. This study aimed to assess the preclinical safety of an indigenously developed dielectric barrier discharge-CAP (DBD) device and its cytotoxic efficacy against melanoma cells while adhering to OECD 402 guidelines for acute dermal toxicity study. The safety evaluation includes ex vivo studies on mouse peritoneal exudates and in vivo acute dermal toxicity tests on Wistar rats.
Methods:
The ex vivo study of mice peritoneal cells treated for up to 120 seconds, showed a survival rate of over 90% up to 90 seconds of CAP treatment for applied voltage 18.6 kV at 20 kHz with no significant difference with control. In the acute dermal toxicity tests, CAP exposure for up to 30 seconds caused minimal inflammatory cell infiltration and no significant Dermal Inflammation Scoring (DIS) (60;1).
Results:
The efficacy study against G361 human melanoma cells showed reduced cell viability by ~50% (MTT assay) upon 30 seconds of CAP treatment for applied voltage 24 kV at 20 kHz through ROS-mediated apoptosis, confirmed by a 3-fold increase in intracellular reactive oxygen species levels and nuclear fragmentation (4',6-diamidino-2-phenylindole staining). Annexin V/PI (propium iodide) staining further revealed ~30% apoptosis after 24 hours of incubation. These findings establish the developed DBD-CAP device is safe for rat skin exposure durations of up to 30 seconds and effective in inducing apoptosis in melanoma cells.
Conclusion:
This study supports CAP's optimization for clinical applications and its integration with existing therapies for enhanced outcomes. However, further study is needed to examine the possible risks associated with using CAP devices in the biomedical field.
More Related Videos
06:09Spatial and Temporal Control of Murine Melanoma Initiation from Mutant Melanocyte Stem Cells
Published on: June 7, 2019
10:05Stimulation of Stem Cell Niches and Tissue Regeneration in Mouse Skin by Switchable Protoporphyrin IX-Dependent Photogeneration of Reactive Oxygen Species In Situ
Published on: May 8, 2020