Related Experiment Video
Updated: Apr 13, 2026

Dual-mode Imaging of Cutaneous Tissue Oxygenation and Vascular Function
Published on: December 8, 2010
Optical coherence tomography needle probe for real-time visualization of temperature-induced phase changes within
Hinnerk Schulz-Hildebrandt1,2,3,4, Michael Wang-Evers5, Naja Meyer-Schell1
1Universität zu Lübeck, Institute of Biomedical Optics, Lübeck, Germany.
None:
Significance: Selective cryolipolysis is a widely used aesthetic procedure that cools subcutaneous adipose tissue to temperatures as low as to induce fat cell destruction. However, real-time monitoring techniques are lacking, limiting the ability to optimize safety and efficacy. Traditional imaging methods either fail to provide adequate penetration depth or lack the resolution necessary for visualizing subcutaneous fatty tissue dynamics. Aim: This paper aims to demonstrate that an optical coherence tomography (OCT) needle probe can be used for real-time observation of temperature-induced changes in subcutaneous fatty tissue, potentially enhancing the assessment and optimization of cryolipolysis procedures. Approach: We developed a side-viewing OCT-based needle probe designed for subcutaneous imaging. The probe consists of a fiber-optic system encased in a transparent, biocompatible polymer catheter with an outer diameter of . A 49-degree angled fiber enables imaging, while a piezoelectric scanning system moves the fiber transversely within the catheter. The probe achieves a lateral resolution of , a working distance of , and a lateral field of view dictated by the scanning system length. OCT imaging was performed on porcine skin with a subcutaneous fat layer >3 cm thick during controlled heating and cooling. Results: OCT imaging revealed increased optical scattering in subcutaneous fatty tissue during cooling, corresponding to the phase transition from liquid to solid. This effect was reversible upon warming, indicating that OCT can dynamically monitor adipocyte crystallization in real time. The observed transition temperatures varied, likely due to differences in lipid composition. Conclusions: OCT-based needle imaging enables direct, high-resolution visualization of adipocyte crystallization, offering a potential tool for optimizing selective cryolipolysis treatments. This technology could improve safety and efficacy by providing real-time feedback on tissue response, facilitating a better understanding of the cooling-induced fat reduction process.
More Related Videos
09:56Universal Hand-held Three-dimensional Optoacoustic Imaging Probe for Deep Tissue Human Angiography and Functional Preclinical Studies in Real Time
Published on: November 4, 2014
09:31In Vivo, Percutaneous, Needle Based, Optical Coherence Tomography of Renal Masses
Published on: March 30, 2015
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):