Relationship between intraperitoneal volume and intraperitoneal pressure during peritoneal dialysis-a pilot study in
Fansan Zhu1, Laura Rosales Merlo1, Lela Tisdale1
1Renal Research Institute, New York City, New York, USA.
Monitoring intraperitoneal pressure (IPP) offers valuable insights into changes of intraperitoneal volume (IPV) during peritoneal dialysis (PD). This study aims to investigate the relationship between IPV and IPP during a PD dwell. Thirteen patients were studied during a 2-h dwell using 2 L of dialysate containing 2.5% dextrose. IPP was measured using a pressure sensor integrated into an automated PD cycler. IPV was monitored concurrently by segmental bioimpedance (Hydra 4200). The density (ρ) of the PD dialysate was measured using a meter, and the creatinine and glucose concentrations in both dialysate (D) and serum (P) were measured pre- and post-PD dwell. A physical model (IPP = ρ × g × h), was used to describe the relationship between IPP and IPV, where h is the apparent dialysate height and g is the gravitational acceleration. The change in IPP (ΔIPP, -21.2 ± 18%) was mainly determined by the change of h (Δh, -20.9 ± 18.5%), while the change ρ (Δρ, -0.34 ± 0.06%), was minor. The study demonstrated an association between ΔIPP and the ratio of D/P creatinine and D/D0 glucose, suggesting that ΔIPP may reflect membrane transport characteristics. Due to its noninvasive and seamless nature, the clinical utility of PD cycler-based measurement of IPP warrants further exploration.
Monitoring intraperitoneal pressure (IPP) offers valuable insights into changes of intraperitoneal volume (IPV) during peritoneal dialysis (PD). This study aims to investigate the relationship between IPV and IPP during a PD dwell. Thirteen patients were studied during a 2-h dwell using 2 L of dialysate containing 2.5% dextrose. IPP was measured using a pressure sensor integrated into an automated PD cycler. IPV was monitored concurrently by segmental bioimpedance (Hydra 4200). The density (ρ) of the PD dialysate was measured using a meter, and the creatinine and glucose concentrations in both dialysate (D) and serum (P) were measured pre- and post-PD dwell. A physical model (IPP = ρ × g × h), was used to describe the relationship between IPP and IPV, where h is the apparent dialysate height and g is the gravitational acceleration. The change in IPP (ΔIPP, -21.2 ± 18%) was mainly determined by the change of h (Δh, -20.9 ± 18.5%), while the change ρ (Δρ, -0.34 ± 0.06%), was minor. The study demonstrated an association between ΔIPP and the ratio of D/P creatinine and D/D0 glucose, suggesting that ΔIPP may reflect membrane transport characteristics. Due to its noninvasive and seamless nature, the clinical utility of PD cycler-based measurement of IPP warrants further exploration.
Related Concept Videos
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Fluid Movement Between Compartments
Dialysis
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
Blood Pressure
Pressure Variation in a Fluid at Rest
When measuring pressure at two different levels within the fluid, the difference in...