Related Experiment Video
Updated: May 22, 2025

Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
Optimizing solvent extraction methods for activated carbon-based passive samplers in atmospheric volatile organic
Se-Eun Jang1, Yong-Hyun Kim2,3,4
1Department of Environment & Energy, Jeonbuk National University, 567 Baekje-Daero, Deokjin-Gu, Jeonju-Si, Jeonbuk State, 54896, Republic of Korea.
Abstract:
A passive sampler was used to effectively monitor trace volatile organic compound (VOC) concentrations in the atmosphere. VOCs are typically extracted from passive samplers using CS2, which is a volatile and hazardous chemical that can leave residues and damage the mass spectrometry (MS) system during gas chromatography (GC)-MS. This study aims to develop and validate alternative solvent extraction methods using acetone, ethanol, n-hexane, and a solution of 99% acetone and 1% CS2 (ATCS) for VOCs from passive samplers using a standard GC-MS system. ATCS had the highest VOC extraction efficiency with the average value of 42.4 ± 21.4%, followed by acetone at 29.9 ± 17.6%. Ethanol and n-hexane exhibited extraction efficiencies of less than 9%. Despite the ATCS extraction efficiency of less than 50%, it demonstrated excellent analytical reproducibility (relative standard deviation of 1.62 ± 0.64%) and detection limit of 20.5 ± 12.9 ppt, which was significantly lower than 1 ppb. When used to extract and analyze VOCs from ambient air samples, ATCS yielded VOC concentrations of 0.57 ± 0.33 ppb, consistent with urban air levels. The variance in the outdoor VOC concentrations was less than 0.1 ppb, confirming its high reproducibility. Thus, the ATCS solvent extraction method developed in this study enables the accurate quantification of trace VOCs below 1 ppb, reduces MS damage, and mitigates health risks to analysts using GC-MS.
More Related Videos
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
10:34Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
Related Concept Videos
Volatilization
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...