Study of In Vivo Glucose Metabolism in High-fat Diet-fed Mice Using Oral Glucose Tolerance Test OGTT and Insulin Tolerance Test ITT
Published on: January 7, 2018
The Oral Glucose Tolerance Test: Changed Results Using Different Drinking Solutions?
Sabine Schipf1, Oliver Kuß2,3,4, Barbara Thorand3,5,6
1Institute for Community Medicine, University Medicine Greifswald, Greifswald, Germany.
Two oral glucose tolerance test (oGTT) solutions, a commercial Accu-Chek Roche and a standardized NRF 13.8, showed no significant clinical differences in 2-hour glucose levels or gastrointestinal side effects. This finding supports the interchangeability of these solutions in diagnostic testing.
Area of Science:
- Endocrinology
- Clinical Chemistry
- Public Health Research
Background:
- The choice of drinking solution for oral glucose tolerance tests (oGTT) can influence results and patient experience.
- Standardized protocols are crucial for accurate diabetes diagnosis and management.
Purpose of the Study:
- To compare the impact of a commercial Accu-Chek Roche solution versus a standardized NRF 13.8 oGTT solution on 2-hour glucose values.
- To assess and compare gastrointestinal side effects associated with each oGTT solution.
Main Methods:
- A subgroup of German National Cohort (NAKO) participants received either the Accu-Chek Roche or NRF 13.8 solution for a 75g oGTT.
- Participants were matched by study center, sex, age, BMI, and fasting glucose.
- 2-hour glucose values were analyzed using intra-class correlations and Bland-Altman plots; coefficients of variation were also calculated.
Main Results:
- The mean difference in 2-hour glucose between the two solutions was -3.4 mg/dL, with no systematic pattern in variability.
- Intra-class correlations for 2-hour glucose were 22%, and coefficients of variation were similar (25% for both).
- Gastrointestinal symptoms like nausea or vomiting occurred in less than 0.1% of participants, with no significant difference between solutions.
Conclusions:
- The Accu-Chek Roche and NRF 13.8 oGTT solutions yield comparable 2-hour glucose values and gastrointestinal side effect profiles.
- These findings suggest that both solutions are clinically interchangeable for performing oral glucose tolerance tests.
More Related Videos
Related Concept Videos
Oral Hypoglycemic Agents: α-Glucosidase Inhibitors
Acarbose and miglitol are...
Oral Hypoglycemic Agents: Biguanides and Glitazones
Oral Hypoglycemic Agents: Glinides
Hypoglycemia and Glucagon
Glucose Homeostasis: Regulation of Blood Glucose
During fasting, when blood glucose levels are low, the pancreas secretes glucagon. it...
Dipeptidyl Peptidase 4 Inhibitors